3.19 lost 10 watts

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

3.19 lost 10 watts

KARL MARDERIAN
After loading 3.19 frimware into my K3, I no longer get 120 watts when  
denting power at maxium. I do get 12 watts on the low scale. I did  
recalibrate my Tx, 1 mw, 5 w and 50 w with dummy load.
  Anyone with the same? Amy insite?
Sent from my iPhone
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: 3.19 lost 10 watts

Iain MacDonnell - N6ML-2


Karl MARDERIAN wrote:
> After loading 3.19 frimware into my K3, I no longer get 120 watts when  
> denting power at maxium. I do get 12 watts on the low scale. I did  
> recalibrate my Tx, 1 mw, 5 w and 50 w with dummy load.
>   Anyone with the same? Amy insite?

Yes, that was an intentional change in the latest firmware. Please read
the release notes when (or before) you upgrade!

* MAX POWER LEVEL NOW 110 W (was 120 W): This is intended
to reduce the possibility of excess KPA3 operating current on some
bands. This might have occurred when using a high power setting
along with low power supply voltage and/or a high load SWR.
(Note: The recommended maximum power setting is still 100 W.)

     ~Iain / N6ML