ERR VCO E00129 on my new KRX3

classic Classic list List threaded Threaded
1 message Options
Reply | Threaded
Open this post in threaded view
|

ERR VCO E00129 on my new KRX3

DaleJ
I finished installing the KRX3 this morning and after setting everything up IAW p.43 of the manual, I went to calibrate the KSYN3.  Everything went along ok until the end of the calibration and the screen said ERR VCO E 00129.  I performed the calibration three times with the same result.  I checked the cables for continuity and that they are firmly plugged into the correct sockets but still no joy.  So I installed the new KSYN3 in the main rx slot and proceeded to do the calibration routine again and it failed.  The problem appears to be in the new KSYN3 unless I'm missing something somewhere.  I gave the board a good visual inspection with my jewelers eye-loupe, but did not see anything obviously wrong with the solder or tracks. I'm guessing maybe one of those crystals went dead.    

I contacted Elecraft support via email, but of course won't hear anything until next week.

73
Dale, k9vuj

K3 S/N 2268
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html