Fw: KPA500 Question re the K3s per band power control

classic Classic list List threaded Threaded
1 message Options
Reply | Threaded
Open this post in threaded view
|

Fw: KPA500 Question re the K3s per band power control

John E. Reiser

----- Original Message -----
From: "John E. Reiser" <[hidden email]>
To: "D Joyce" <[hidden email]>
Sent: Sunday, August 14, 2011 8:50 AM
Subject: Re: [Elecraft] KPA500 Question re the K3s per band power control


> Hi Doug,VE3MV,
>
> PWR ON is not the right control.  Try setting BAND CHG to STBY and you
> will see what I'm concerned with.
>
> By the way, the reason that I want to have this working right is that two
> of my WARC-band antennas are PAR EndFedz which can only take 100 watts.
> If I am on 20 meters with the beam and have the amp on with 500 watts and
> then go to 30 meters, I want the amp to automatically go to standby and
> the power from the K3 to go up to 100 watts just because of the band
> change.  It's supposed to work that way, but doesn't.
>
> 73, John
>
>
> ----- Original Message -----
> From: "D Joyce" <[hidden email]>
> To: "John E. Reiser" <[hidden email]>; "Elecraft List"
> <[hidden email]>
> Sent: Sunday, August 14, 2011 8:27 AM
> Subject: Re: [Elecraft] KPA500 Question re the K3s per band power control
>
>
>> GM John:
>>
>> I'm not seeing that problem here with KPA500 s/n 234 and a recent K3/10
>> (s/n 54xx).  I'm using FW 4.39 in the K3 and FW 1.11 in the KPA500.
>> (Gary sent me this most recent FW for the Amp on Fri).
>>
>> I changed the PWR ON config in the KPA500 to "STBY" and the only thing it
>> affects is the power setting when turning the Amp On.  Changing bands
>> from either the K3 or the Amp doesn't change OPER to STBY or STBY to
>> OPER. I've set the STBY power level to be 5 W and the OPER power level to
>> be 125W (approx 8 W from the K3) on all bands (all in CW mode).  Then
>> regardless of which unit is used to change bands and whether the Amp is
>> in OPER or STBY the power levels are as just indicated.  It works as
>> expected.
>>
>> Hope that helps.
>>
>> 73,  Doug  VE3MV
>>
>> ----- Original Message -----
>> From: "John E. Reiser" <[hidden email]>
>> To: "D Joyce" <[hidden email]>; "Elecraft List"
>> <[hidden email]>
>> Sent: Saturday, August 13, 2011 6:24 PM
>> Subject: Re: [Elecraft] KPA500 Question re the K3s per band power control
>>
>>
>>> Yes, that much works here too.
>>>
>>> What doesn't work is setting the KPA500 MENU: BAND CHG to STBY and
>>> expecting that the power out from the K3 will reliably switch to higher
>>> power whenever the amp is in STANDBY mode, both whether invoked by the
>>> button on the amp or by simply changing bands on the K3, and then
>>> reliably dropping to an appropriate lower level whenever the amp is put
>>> in OPERATE mode by tapping the operate/standby button on the amp.
>>>
>>> Whew!  I got it all into one sentence.  With 300+ KPA500s out there, am
>>> I the only one to observe this?  Come on guys, can't anyone test this
>>> for me with their setup?  How about it W4TV?
>>>
>>> 73, John, W2GW
>>
>>
>


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html