turned off/uplugged the k3 last night, all was working well
Turned on the K3 this morning, had both error messages "ERR AT3" and "ERR
PL1"
"ERR PLI" was the most immediate, in this state there was no main vfo
tuning, so I consulted the manual
did a "config: vco md" recalibration of vco1. It failed with error message
err05 on the display
just on a hunch, I wondered if anything memory wise had got corrupted so I
reloaded ALL the 3.14/dsp2.16 software
After finishing, i had NO "ERR AT3" error, but i did still have the "ERR
PL1" error. I wasnt too surprised at the latter error as it had just failed
calibration
redid the "config: vco md" recalibration of vco1, it passed this time
On power off/on no error messages
All is now well again in the land of the K3
Incident cost me 30 minutes of valuable painting time before the texas heat
calls a timeout!