Mike,
Just to let you know that I have received a very positive response from Elecraft about the K2's AGC Threshold setting problem.. Your DMM appears to be fine, and I hope that the info I sent you solves your problem. Would appreciate hearing when you have time. 73, Geoff GM4ESD _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
|
Geoff, I think I'm all set for now, and the work is progressing nicely. I
would be interested in hearing Elecrafts thoughts on the AGC circuit, and what you thought the problem was. Thanks again for the help. Mike, W8ENG ----- Original Message ----- From: "Geoffrey Mackenzie-Kennedy" <[hidden email]> To: "Mike, W8ENG" <[hidden email]> Cc: "Elecraft Discussion List" <[hidden email]> Sent: Thursday, November 18, 2004 4:51 PM Subject: K2 AGC Threshold. > Mike, > > Just to let you know that I have received a very positive response from > Elecraft about the K2's AGC Threshold setting problem.. > > Your DMM appears to be fine, and I hope that the info I sent you solves your > problem. Would appreciate hearing when you have time. > > 73, > > Geoff GM4ESD > > _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
|
Mike,
Great to hear that you are all set and that the work is progressing - and you are very welcome. About the problem. Your K2 and mine wanted a higher voltage at U2 pin 5 than the "normal" to prevent the AGC working on the receiver's own internal noise. The AGC Threshold was too low and could not be raised because the adjustment pot R1 had reached the end of its travel. The reason that we could not get the voltage at U2 pin 5 to the value required for a proper setting of the AGC threshold was simply that the output voltage from the 8 volt regulator was / is less than 8 volts, but still within the allowed tolerance, and the divider composed of parts of RP6 along with R1 could not cater to this lower voltage. Adding the 27K resistor across RP6 (3-4) compensates enough for the low output from the 8V regulators that we have and, in my case, results in the wiper of R1 being close to mid-travel when set for the AGC threshold that I like. But I must stress that this "fix" is for our K2s. The global modification would have to cater for all DC voltage tolerances, AGC closed loop tolerances, receiver gain tolerances and so on, if one goes whole hog - which might not be necessary. But I'll leave those sums for the lads at Elecraft ! Hope that answers your question, and have fun. 73, Geoff GM4ESD ----- Original Message ----- From: "Mike, W8ENG" <[hidden email]> To: "Geoffrey Mackenzie-Kennedy" <[hidden email]> Cc: "Elecraft Discussion List" <[hidden email]> Sent: Saturday, November 20, 2004 2:11 AM Subject: Re: K2 AGC Threshold. > Geoff, I think I'm all set for now, and the work is progressing nicely. I > would be interested in hearing Elecrafts thoughts on the AGC circuit, and > what you thought the problem was. Thanks again for the help. > > Mike, W8ENG > > > _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
| Free forum by Nabble | Edit this page |