K2 Dropping Out at Load

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

K2 Dropping Out at Load

ny4g
This is the first time this has happened on my K2.  It dropped out on key down at about 70 watts.  I am powered with a 33a-h SLA battery.  What can possibly cause the cutout on power?
NY4G
Reply | Threaded
Open this post in threaded view
|

Re: K2 Dropping Out at Load

Don Wilhelm-4
Over 5 amps of current into the base K2 will cause the resettable fuse
to trip.
Did you see a HiCur message?
Check the current draw of the base K2 (tap DISPLAY) during transmit - it
should not exceed 3.50 amps.

73,
Don W3FPR

On 10/24/2011 10:57 AM, ny4g wrote:
> This is the first time this has happened on my K2.  It dropped out on key
> down at about 70 watts.  I am powered with a 33a-h SLA battery.  What can
> possibly cause the cutout on power?
> NY4G
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html