Dennis,
It sounds like you have the right one - the '100J' is the significant
marking - the '10' part is the 2 significant digits and the '0' is the
'multiplier' (number of zeros to add), so '100' means 10 pf. - similarly
'103' would mean 10,000 pf or 0.01 uf.
73,
Don W3FPR
> -----Original Message-----
>
> I need know if I am using the right component for const of Freq
> Counter Probe as described on Page 45. It calls
> for a 10pF axial-lead cap. I have something that looks like a
> small yellow resistor without stripes, with markings
> "K1G 100J and BK4 0545" is this the right component for the
> probe? Dennis Vavra, AD5LY
>
--
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.5.432 / Virus Database: 268.16.13/632 - Release Date: 1/16/2007