[K2] - KDSP2 Installation Clearances

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

[K2] - KDSP2 Installation Clearances

Gordon & Lois Duff
I am in the process of installing the KDSP2 on the Control Board.  When the
KDSP2 is plugged into J1 and J2 the connectors do not fully mate; the board
is resting on C28, C29 and L1.

 

C28 , C29 and L1 are all flush mounted to the Control Board.  It appears
that C28 and C29 are not contacting any of the Control Board circuitry.  Is
this normal?

 

Gordon, KA2NLM

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: [K2] - KDSP2 Installation Clearances

KK7P

> I am in the process of installing the KDSP2 on the Control Board.  When the
> KDSP2 is plugged into J1 and J2 the connectors do not fully mate;
The spacer/hardware stackup should be determining the spacing.  The
KDSP2 (not DSP) PC board has no component leads or other protrusions
where it sits over the tall components on the control board, as the
clearance is very, small.

73,

Lyle KK7P