The instructions with the resistance check chart on page 44 of the Rev G KPA100 manual are very explicit about the measurement on J3, namely that the electrolytic capacitor in the 12V line causes this measurement to appear as a short initially, and then slowly go up to a resistance value within range.
I am seeing exactly the same behavior on the Q1 and Q2's collectors and D13's cathode, starts at 0 ohms and ramps up to an in-range value in a number of seconds. Since the instructions were so explicit about J3 and didn't mention these other measurements, I'd like to make sure that this behavior is OK.
Thanks -
Bruce
Bruce Rosen
K1FFX
K2/100 6982 KSB2 KAT100-1 KAF2 KIO2