K2/KSB2 problem

classic Classic list List threaded Threaded
1 message Options
Reply | Threaded
Open this post in threaded view
|

K2/KSB2 problem

F5UL-2
Hello all the team, particularly DON!

Since some week I had a KSB2 problem. The K2 is working perfectly in CW, alone, or with the KPA100,
with the KSB2 position jumpered. If I put KSB2 in place, the K2 Smeter display go to S9 + 40
block the receiver and too, does not switch in Tx when I close either the key or the mike PTT.
I did this morning voltages test on KSB2, and the following list is the values not normal, as
indicated page23 of KSB2Assembly instruction :

U1-12 = 5.02 (TXC)
U1-14 = 5.21
U1-16 = 0.00
U1-17 = 5.23
U1-21 = 0.00 (RXS)
U1-22 = 4.27 (RXC)
U1-28 = 4.92

U2-5 = 5.36

U3 OK

U4-3 = 5.24

All these values where obtained in Rx. I did not check them in Tx as it was impossible to switch in Tx mode!
All values not noted where per the book!

If I remember well, the U1 is a new one!
Best regards to Elecraft
F5UL Bob

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html