K2 - Lost 40m Tx after install of K60XV option

classic Classic list List threaded Threaded
5 messages Options
Reply | Threaded
Open this post in threaded view
|

K2 - Lost 40m Tx after install of K60XV option

Neil Zampella
Hi all,

need some advice.   I have a K2, and it was working fine.   Then I put
together the K60XV option and installed it.   Messed something up as 40M
Tx went away.    The rig switches to Tx, but I do not see any power
coming out of the system.

Any suggestions on what I messed up :(

Thanks,

Neil, KN3ILZ


---
This email has been checked for viruses by AVG.
https://www.avg.com

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K2 - Lost 40m Tx after install of K60XV option

Don Wilhelm
Neil,

Does 60 meters work, but not 40 meters?

The only things that could 40 meters to fail after installing the K60XV are:

1) C6 is not the correct 4.7 pF value - it will be marked either 4.7 or 479.

2) Relay K1 not working properly, check the orientation and soldering.
3) P2 and/or RF J15 not installed properly.

73,
Don W3FPR

On 8/5/2019 11:14 AM, Neil Zampella wrote:
> Hi all,
>
> need some advice.   I have a K2, and it was working fine.   Then I put
> together the K60XV option and installed it.   Messed something up as 40M
> Tx went away.    The rig switches to Tx, but I do not see any power
> coming out of the system.
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K2 - Lost 40m Tx after install of K60XV option

Neil Zampella
Don,

I don't see 60M working either.    I'll check these tomorrow after work.

Neil

On 8/5/2019 2:20 PM, Don Wilhelm wrote:

> Neil,
>
> Does 60 meters work, but not 40 meters?
>
> The only things that could 40 meters to fail after installing the
> K60XV are:
>
> 1) C6 is not the correct 4.7 pF value - it will be marked either 4.7
> or 479.
>
> 2) Relay K1 not working properly, check the orientation and soldering.
> 3) P2 and/or RF J15 not installed properly.
>
> 73,
> Don W3FPR
>
> On 8/5/2019 11:14 AM, Neil Zampella wrote:
>> Hi all,
>>
>> need some advice.   I have a K2, and it was working fine.   Then I put
>> together the K60XV option and installed it.   Messed something up as 40M
>> Tx went away.    The rig switches to Tx, but I do not see any power
>> coming out of the system.
>>
>

---
This email has been checked for viruses by AVG.
https://www.avg.com

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K2 - Lost 40m Tx after install of K60XV option

Alan D. Wilcox, W3DVX
Neil,
When you did initial setup of the K60XV, did you
set D19 to Yes?
Cheers,
Alan

Alan D. Wilcox, W3DVX
570-916-9590 (cell, text)
https://WilcoxEngineering.com
http://www.eham.net/reviews/detail/6768 ... Elecraft Client Comments
http://amazon.com/author/alandwilcox
Williamsport, PA 17701

> On Aug 5, 2019, at 19:43, Neil Zampella <[hidden email]> wrote:
>
> Don,
>
> I don't see 60M working either.    I'll check these tomorrow after work.
>
> Neil
>
> On 8/5/2019 2:20 PM, Don Wilhelm wrote:
>> Neil,
>>
>> Does 60 meters work, but not 40 meters?
>>
>> The only things that could 40 meters to fail after installing the
>> K60XV are:
>>
>> 1) C6 is not the correct 4.7 pF value - it will be marked either 4.7
>> or 479.
>>
>> 2) Relay K1 not working properly, check the orientation and soldering.
>> 3) P2 and/or RF J15 not installed properly.
>>
>> 73,
>> Don W3FPR
>>
>> On 8/5/2019 11:14 AM, Neil Zampella wrote:
>>> Hi all,
>>>
>>> need some advice.   I have a K2, and it was working fine.   Then I put
>>> together the K60XV option and installed it.   Messed something up as 40M
>>> Tx went away.    The rig switches to Tx, but I do not see any power
>>> coming out of the system.
>>>
>>
>
> ---
> This email has been checked for viruses by AVG.
> https://www.avg.com
>
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [hidden email]

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K2 - Lost 40m Tx after install of K60XV option

Neil Zampella
In reply to this post by Neil Zampella
Thanks to all who sent advice ...  Don (as usual) steered me in the
right direction.

I need to replace the K1 relay as I accidentally touched it when
removing the RF Board C6 capacitor for the K60XV installation. Didn't
think much at the time, but definitely bit me in the tail here.

Neil, KN3ILZ

On 8/5/2019 7:43 PM, Neil Zampella wrote:

> Don,
>
> I don't see 60M working either.    I'll check these tomorrow after work.
>
> Neil
>
> On 8/5/2019 2:20 PM, Don Wilhelm wrote:
>> Neil,
>>
>> Does 60 meters work, but not 40 meters?
>>
>> The only things that could 40 meters to fail after installing the
>> K60XV are:
>>
>> 1) C6 is not the correct 4.7 pF value - it will be marked either 4.7
>> or 479.
>>
>> 2) Relay K1 not working properly, check the orientation and soldering.
>> 3) P2 and/or RF J15 not installed properly.
>>
>> 73,
>> Don W3FPR
>>
>> On 8/5/2019 11:14 AM, Neil Zampella wrote:
>>> Hi all,
>>>
>>> need some advice.   I have a K2, and it was working fine. Then I put
>>> together the K60XV option and installed it.   Messed something up as
>>> 40M
>>> Tx went away.    The rig switches to Tx, but I do not see any power
>>> coming out of the system.
>>>
>>

---
This email has been checked for viruses by AVG.
https://www.avg.com

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html