K2 S Meter

classic Classic list List threaded Threaded
5 messages Options
Reply | Threaded
Open this post in threaded view
|

K2 S Meter

KR4OW
Hello all I am at the test 1 phase of the build
The problem I am having is that when I set the Slo or
SHi the far right dot is the only one lighting up.
It says in the manual that (Slo) the far left led
and it is on 10. I double checked my agc and it is at
3.80 so that is not in question is there something
I am overlooking?? if so what? or am I looking at a
mistake in one of my steps?
Thanks
David KR4OW


               
__________________________________
Do you Yahoo!?
Yahoo! Mail Address AutoComplete - You start. We finish.
http://promotions.yahoo.com/new_mail 
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft    Help:  http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: K2 S Meter

JEAN-FRANCOIS MENARD-2
Be sure to turn the RF Gain fully clockwise and counterclockwise as
describe in the manual when ajusting S Lo and S Hi.

Le 04-07-02, à 23:57, David N. a écrit :

> Hello all I am at the test 1 phase of the build
> The problem I am having is that when I set the Slo or
> SHi the far right dot is the only one lighting up.
> It says in the manual that (Slo) the far left led
> and it is on 10. I double checked my agc and it is at
> 3.80 so that is not in question is there something
> I am overlooking?? if so what? or am I looking at a
> mistake in one of my steps?
> Thanks
> David KR4OW
>
>
>
> __________________________________
> Do you Yahoo!?
> Yahoo! Mail Address AutoComplete - You start. We finish.
> http://promotions.yahoo.com/new_mail
> _______________________________________________
> Elecraft mailing list
> Post to: [hidden email]
> You must be a subscriber to post to the list.
> Subscriber Info (Addr. Change, sub, unsub etc.):
> http://mailman.qth.net/mailman/listinfo/elecraft    Help:  
> http://mailman.qth.net/subscribers.htm
> Elecraft web page: http://www.elecraft.com
===============================================
Jean-François Ménard / VA2VYZ
[hidden email]

Club d'Astronomie Amateur de Sherbrooke
Club Radio Amateur de l'Estrie

Mon site web personnel : http://homepage.mac.com/jfmenard
===============================================

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft    Help:  http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: K2 S Meter

dmb@lightstream.net
Hello Jean-Francois,

Also, be sure that the AGC is in fact turned ON. To be certain that it's
on, simply tap the AGC button once. If it was previously off, that will
turn it on, and if it was on already, it will simply change the AGC
time-constant from either fast to slow, or the other way around.

If you are concerned that you never see more thatn one of the S-Meter
LED's lit at a time, then you most likely have the "DOT" mode selected,
as opposed to the "BARGRAPH" mode. To change it, locate the "GRPH" menu
item on the Primary Menu. You'll notice three possible settings for GRPH:
bAr (Bargraph)
OFF (No S-Meter LED's will be displayed)
dOt (Only a single LED at a time will be displayed, as a power-saving
feature)

If you select "bAr" you should see all S-Meter LED segments lit when the
right-most LED is lit.

Hope this helps.

73, Dale / WA8SRA

JEAN-FRANCOIS MENARD wrote:

> Be sure to turn the RF Gain fully clockwise and counterclockwise as
> describe in the manual when ajusting S Lo and S Hi.
>
> Le 04-07-02, à 23:57, David N. a écrit :
>
>> Hello all I am at the test 1 phase of the build
>> The problem I am having is that when I set the Slo or
>> SHi the far right dot is the only one lighting up.
>> It says in the manual that (Slo) the far left led
>> and it is on 10. I double checked my agc and it is at
>> 3.80 so that is not in question is there something
>> I am overlooking?? if so what? or am I looking at a
>> mistake in one of my steps?
>> Thanks
>> David KR4OW
>>
>

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft    Help:  http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: K2 S Meter

JEAN-FRANCOIS MENARD-2
It's not me that have problem... it's David KR4OW

Mine works fine, really fine !!!

Le 04-07-03, à 15:41, Dale Boresz a écrit :

> Hello Jean-Francois,
>
> Also, be sure that the AGC is in fact turned ON. To be certain that
> it's on, simply tap the AGC button once. If it was previously off,
> that will turn it on, and if it was on already, it will simply change
> the AGC time-constant from either fast to slow, or the other way
> around.
>
> If you are concerned that you never see more thatn one of the S-Meter
> LED's lit at a time, then you most likely have the "DOT" mode
> selected, as opposed to the "BARGRAPH" mode. To change it, locate the
> "GRPH" menu item on the Primary Menu. You'll notice three possible
> settings for GRPH:
> bAr (Bargraph)
> OFF (No S-Meter LED's will be displayed)
> dOt (Only a single LED at a time will be displayed, as a power-saving
> feature)
>
> If you select "bAr" you should see all S-Meter LED segments lit when
> the right-most LED is lit.
>
> Hope this helps.
>
> 73, Dale / WA8SRA
>
> JEAN-FRANCOIS MENARD wrote:
>
>> Be sure to turn the RF Gain fully clockwise and counterclockwise as
>> describe in the manual when ajusting S Lo and S Hi.
>>
>> Le 04-07-02, à 23:57, David N. a écrit :
>>
>>> Hello all I am at the test 1 phase of the build
>>> The problem I am having is that when I set the Slo or
>>> SHi the far right dot is the only one lighting up.
>>> It says in the manual that (Slo) the far left led
>>> and it is on 10. I double checked my agc and it is at
>>> 3.80 so that is not in question is there something
>>> I am overlooking?? if so what? or am I looking at a
>>> mistake in one of my steps?
>>> Thanks
>>> David KR4OW
>>>
>>
>
> _______________________________________________
> Elecraft mailing list
> Post to: [hidden email]
> You must be a subscriber to post to the list.
> Subscriber Info (Addr. Change, sub, unsub etc.):
> http://mailman.qth.net/mailman/listinfo/elecraft    Help:  
> http://mailman.qth.net/subscribers.htm
> Elecraft web page: http://www.elecraft.com
===============================================
Jean-François Ménard / VA2VYZ
[hidden email]

Club d'Astronomie Amateur de Sherbrooke
Club Radio Amateur de l'Estrie

Mon site web personnel : http://homepage.mac.com/jfmenard
===============================================

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft    Help:  http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: K2 S Meter

dmb@lightstream.net
Sorry, yes I realized that shortly after sending it, but figured David
would still see it. I need to be more careful when looking at the
hierarchy of messages... :-)

73, Dale / WA8SRA

JEAN-FRANCOIS MENARD wrote:

> It's not me that have problem... it's David KR4OW
>
> Mine works fine, really fine !!!
>
> Le 04-07-03, à 15:41, Dale Boresz a écrit :
>
>> Hello Jean-Francois,
>>
>> Also, be sure that the AGC is in fact turned ON. To be certain that
>> it's on, simply tap the AGC button once. If it was previously off,
>> that will turn it on, and if it was on already, it will simply change
>> the AGC time-constant from either fast to slow, or the other way around.
>>
>> If you are concerned that you never see more thatn one of the S-Meter
>> LED's lit at a time, then you most likely have the "DOT" mode
>> selected, as opposed to the "BARGRAPH" mode. To change it, locate the
>> "GRPH" menu item on the Primary Menu. You'll notice three possible
>> settings for GRPH:
>> bAr (Bargraph)
>> OFF (No S-Meter LED's will be displayed)
>> dOt (Only a single LED at a time will be displayed, as a power-saving
>> feature)
>>
>> If you select "bAr" you should see all S-Meter LED segments lit when
>> the right-most LED is lit.
>>
>> Hope this helps.
>>
>> 73, Dale / WA8SRA
>>
>> JEAN-FRANCOIS MENARD wrote:
>>
>>> Be sure to turn the RF Gain fully clockwise and counterclockwise as
>>> describe in the manual when ajusting S Lo and S Hi.
>>>
>>> Le 04-07-02, à 23:57, David N. a écrit :
>>>
>>>> Hello all I am at the test 1 phase of the build
>>>> The problem I am having is that when I set the Slo or
>>>> SHi the far right dot is the only one lighting up.
>>>> It says in the manual that (Slo) the far left led
>>>> and it is on 10. I double checked my agc and it is at
>>>> 3.80 so that is not in question is there something
>>>> I am overlooking?? if so what? or am I looking at a
>>>> mistake in one of my steps?
>>>> Thanks
>>>> David KR4OW
>>>>
>

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft    Help:  http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com