Bob,
Don't even think about using that yellow core at T3 - that core must
have a high permeability (as do all the other transformers except T5).
T5 is really a tapped inductor rather than a true transformer.
email
[hidden email] and ask for the correct core.
73,
Don W3FPR
On 2/21/2012 10:09 AM, Bob Mallory wrote:
> Just getting to the Toroid Building section of the base K2. I've noticed
> that I don't have a FT50-43 (.5" gray Ferrite Core), but I have two of the
> T50-6's, the Yellow Iron-powder core.
>
> Does anyone know or have tried the Yellow Iron-powder core for the T3
> winding? Or should I contact Elecraft to get the correct one?
>
> Thanks...
> Bob K8TOB
>