Pippo,
Check to be certain Control Board RP4 is well soldered. If so, I would
believe all is well. Your readings vary by less than 10% from typical,
which is usually OK. If your DMM is battery powered, you may want to
check for a weak battery which can cause higher than actual resistance
readings.
73,
Don W3FPR
On 10/26/2010 10:00 AM, Giuseppe Sorrentino wrote:
> Hy to all. Just performed the test as indicated on page 22 of the manual i have
> 2 values different from ranges indicated.
>
> U6 pin 29 indicated 70-90 k i have 96,5 k
> U6 pin 30 indicated 70-90 k i have 96,7 k
>
> Is there anyone (i know he is out there ;D) who can tell me if they
> are unacceptable values and what to do to solve the problem?? All the other
> values are good as indicated on the manual.
> IZ2NYY
> Giuseppe "Pippo" Sorrentino
> Milano ITALY
>
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.html