K2 messages

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

K2 messages

wsm-3
Hello
Recently I have started getting two different messages when changing
bands on my k2 # 5846.
One is "fase", and the other is "slo". I have never gotten these
before, until after I did a little adjusting on my SSB adapter.
I can't find anything about them in the manual.
Anyone have any idea what I did to cause this?
Thanks
Scott N5SM

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: K2 messages

Don Wilhelm-3
Scott,

That is the normal message when you tap the AGC button - Fast AGC or Slo
AGC.

They have nothing to do directly with the KSB2, although you may have
disturbed something that was loose or has an intermittent solder connection.

If you are getting those messages without any obvious action, look on
the Control Board and Front Panel Board for any sign of a bad solder
connection or something not soldered.

73,
Don W3FPR

[hidden email] wrote:
> Hello
> Recently I have started getting two different messages when changing
> bands on my k2 # 5846.
> One is "fase", and the other is "slo". I have never gotten these
> before, until after I did a little adjusting on my SSB adapter.
> I can't find anything about them in the manual.
> Anyone have any idea what I did to cause this?
> Thanks
> Scott N5SM
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com