K3 1 milliwatt calibration failed

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

K3 1 milliwatt calibration failed

C L Jonkers
After installing new syns and making other mods calibration was going well until the 1 mw test.  Then:

IsSamplingComplete: Unexpected response 'DB 0.72 MW;' to 'DB;'. State 220

Any help appreciated.
73,
Neil  NJ6L
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K3 1 milliwatt calibration failed

C L Jonkers
Thanks to Olli - DH8BQA for the good advice to manually run the calibration. It worked.
73,  Neil NJ6L