[K3] A momentary BAT LOW warning

classic Classic list List threaded Threaded
7 messages Options
Reply | Threaded
Open this post in threaded view
|

[K3] A momentary BAT LOW warning

Barry
Was playing around in the contest last night and noticed BAT LOW momentarily
flash across the screen.  I'm using a 70A Astron supply with very little
else on it.  Power connector is tight.  ANy thoughts?

Tnx,
Barry W2UP



--
Sent from: http://elecraft.365791.n2.nabble.com/
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: [K3] A momentary BAT LOW warning

Ken Wagner K3IU
Check BAT MIN in the Config menu.
Default is 11 Volts but is adjustable

On 3/4/2018 8:33 AM, Barry wrote:

> Was playing around in the contest last night and noticed BAT LOW momentarily
> flash across the screen.  I'm using a 70A Astron supply with very little
> else on it.  Power connector is tight.  ANy thoughts?
>
> Tnx,
> Barry W2UP
>
>
>
> --
> Sent from: http://elecraft.365791.n2.nabble.com/
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [hidden email]
>

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: [K3] A momentary BAT LOW warning

Barry
Yes, BAT MIN is set for 11, and my metered Astron is about 14,
Barry W2UP



--
Sent from: http://elecraft.365791.n2.nabble.com/
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: [K3] A momentary BAT LOW warning

Barry
In transmit, the voltage was dropping from 13.3 to about 11 at the radio.
The ground wire side of the power cable had worked loose within its terminal
lug at the power supply, causing excess drop.  Reattached and now the drop
is just a few tenths of a volt.  Problem solved.  

Barry W2UP



--
Sent from: http://elecraft.365791.n2.nabble.com/
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: [K3] A momentary BAT LOW warning

Don Wilhelm
Thanks for that information.  This is just one example of those things
that are first blamed on some fault in the rig turns out to be a fault
with something connected to the rig.

That is not limited to Elecraft gear - it can happen with any rig.

73,
Don W3FPR

On 3/4/2018 11:03 AM, Barry wrote:
> In transmit, the voltage was dropping from 13.3 to about 11 at the radio.
> The ground wire side of the power cable had worked loose within its terminal
> lug at the power supply, causing excess drop.  Reattached and now the drop
> is just a few tenths of a volt.  Problem solved.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: [K3] A momentary BAT LOW warning

Bill Frantz
Yup. I found a similar problem in my solar charging system.
There was a large loss in the curent/voltage meter. I found it
because the inline auto fuse holders were warm to the touch. It
confused the charge controller leading to slow charging. I'm
still trying to come up with a good fix, but now I just remove
the meter from the system.

73 Bill AE6JV

On 3/4/18 at 8:53 AM, [hidden email] (Don Wilhelm) wrote:

>Thanks for that information.  This is just one example of those
>things that are first blamed on some fault in the rig turns out
>to be a fault with something connected to the rig.
>
>That is not limited to Elecraft gear - it can happen with any rig.
>
>73,
>Don W3FPR
>
>On 3/4/2018 11:03 AM, Barry wrote:
>>In transmit, the voltage was dropping from 13.3 to about 11 at the radio.
>>The ground wire side of the power cable had worked loose within its terminal
>>lug at the power supply, causing excess drop.  Reattached and now the drop
>>is just a few tenths of a volt.  Problem solved.
-----------------------------------------------------------------------
Bill Frantz        | Concurrency is hard. 12 out  | Periwinkle
(408)356-8506      | 10 programmers get it wrong. | 16345
Englewood Ave
www.pwpconsult.com |                - Jeff Frantz | Los Gatos,
CA 95032

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: [K3] A momentary BAT LOW warning

Dennis Moore
In reply to this post by Barry
I've been having a similar BAT LOW issue only in digital modes when
running more than 80w out. This past weekend I picked up some 45A APP
connectors and 8 ga wire, made a new 5' power cable and all is well. 100
watts with no issue.

73, Dennis NJ6G

On 3/4/2018 08:03, Barry wrote:
> In transmit, the voltage was dropping from 13.3 to about 11 at the radio.
> The ground wire side of the power cable had worked loose within its terminal
> lug at the power supply, causing excess drop.  Reattached and now the drop
> is just a few tenths of a volt.  Problem solved.
>
> Barry W2UP

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]