K3 Compression meter scale

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

K3 Compression meter scale

K2QI
Hello all,

 

Does the compression setting directly correlate to the scale on the LCD?
For example if turn compression to 10, the actual compression amount is more
like 2-3 dB instead of 10 as I would expect.  The meter deflects to the 2nd
or 3rd line between 0 and 10.  If I turn it to 20, the meter deflects to
between 10 and 20.

 

73 de James K3JPS

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
--... ...-- -.. . .--- .- -- . ...
Reply | Threaded
Open this post in threaded view
|

Re: K3 Compression meter scale

KK7P
> Does the compression setting directly correlate to the scale on the LCD?

No.

The CMP reading is the instantaneous amount of compression, with a bit
of decay time so you can see the peak if it is changing rapidly.

The value displayed in the VFO B area is just a relative number relating
to the amount of rotation of the control.

73,

Lyle KK7P

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html