K3/P3 Question about Bandwidth display on P3

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

K3/P3 Question about Bandwidth display on P3

NK7Z
Hello,

I just noticed what may be a bug in the L3/P3 software.

Setup:
1.  Using the K3/P3 combination

2.  Using a macro to change bandwidth launched from the P3, via the
Elecraft Utility program.

3.  P3 set up to show bandwidth by making the cursor line running
vertically wider of narrower.

What happens:
While in CW, or SSB, (no other modes tested), if I am at 2.4 KHz
bandwidth, (and the P3 is showing the correct BW on the screen via the
width of the cursor), and I initiate a BW change using the Macro Editor
utility Elecraft provides, using the macro command, "BW00300;", the
bandwidth changes on the K3, but the display of bandwidth on the P3 does
not change width.

If I then manually turn the BW control on the K3, no matter how small a
change, the bandwidth on the P3 then instantly reverts to correctly
showing the bandwidth.

An example...  I set the bandwidth via the K3, and the bandwidth updates
fine on the P3, and K3.

I then unleash a single macro as described above, (from the P3 utility
program), the K3 changes bandwidth correctly, but the P3 does not
indicate the change, by changing the display cursor width.

If I then launch more BW changing macros of the form BWXXXXX;, from the
P3 Utility, or from my Genovation Keypad, no changes are shown on the
P3, with regards to width, while the K3 always goes to the specified
bandwidth correctly.

If I then just touch the BW knob on the K3 only enough to trigger the
encoder, (any change, no matter how small) the P3 reverts to the correct
BW display width.

Discussion:
Has anyone else seen this behavior?  I am pretty sure that when I
created all of the BW macros for my Genovation keypad, this was not
happening.  So I think this happened sometime in the last year.

I noticed this while changing bandwidths using my Genovation keypad
today demoing the K3/P3 to a friend.  I then removed all of the
Genovation items, and tested again, the problem persists, so it is NOT
the Genovation keypad.

I suspect this is a bug and will need to be addressed by Elecraft.

--
73s and thanks,
Dave
NK7Z
http://www.nk7z.net
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K3/P3 Question about Bandwidth display on P3

tomb18
HiThe command you are using to change the bandwidth is incorrect. It isBWXXXX; not BWXXXXX;You supply bandwidth in 10hz increments. Thus for 300hz you issue BW0030;This is likely the source of your error.I have a bit of experience in programming the K3 and I have found only 4 bugs, that's it. Whether they are bugs or the documentation in wrong is debatable. But the BWXXXX command isn't in error.73 Tomva2fsq.com 


Sent from my Samsung Galaxy smartphone.
-------- Original message --------From: Dave Cole <[hidden email]> Date: 2016-11-23  5:53 PM  (GMT-05:00) To: [hidden email] Subject: [Elecraft] K3/P3 Question about Bandwidth display on P3
Hello,

I just noticed what may be a bug in the L3/P3 software.

Setup:
1.  Using the K3/P3 combination

2.  Using a macro to change bandwidth launched from the P3, via the
Elecraft Utility program.

3.  P3 set up to show bandwidth by making the cursor line running
vertically wider of narrower.

What happens:
While in CW, or SSB, (no other modes tested), if I am at 2.4 KHz
bandwidth, (and the P3 is showing the correct BW on the screen via the
width of the cursor), and I initiate a BW change using the Macro Editor
utility Elecraft provides, using the macro command, "BW00300;", the
bandwidth changes on the K3, but the display of bandwidth on the P3 does
not change width.

If I then manually turn the BW control on the K3, no matter how small a
change, the bandwidth on the P3 then instantly reverts to correctly
showing the bandwidth.

An example...  I set the bandwidth via the K3, and the bandwidth updates
fine on the P3, and K3.

I then unleash a single macro as described above, (from the P3 utility
program), the K3 changes bandwidth correctly, but the P3 does not
indicate the change, by changing the display cursor width.

If I then launch more BW changing macros of the form BWXXXXX;, from the
P3 Utility, or from my Genovation Keypad, no changes are shown on the
P3, with regards to width, while the K3 always goes to the specified
bandwidth correctly.

If I then just touch the BW knob on the K3 only enough to trigger the
encoder, (any change, no matter how small) the P3 reverts to the correct
BW display width.

Discussion:
Has anyone else seen this behavior?  I am pretty sure that when I
created all of the BW macros for my Genovation keypad, this was not
happening.  So I think this happened sometime in the last year.

I noticed this while changing bandwidths using my Genovation keypad
today demoing the K3/P3 to a friend.  I then removed all of the
Genovation items, and tested again, the problem persists, so it is NOT
the Genovation keypad.

I suspect this is a bug and will need to be addressed by Elecraft.

--
73s and thanks,
Dave
NK7Z
http://www.nk7z.net
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]