K3 PA Temp Reading Unstable

paulb

Hi folks

K3 here has developed a slight problem with the PA temp sensing..
it is flicking between normal and +40 several times per minute.
noticed the fans starting in a very cold shack RX only running.
This may have been happening for a while, but never noticed until
the cooler mornings.

Havn't taken a look at the PA or circuits yet, wonder if another user
has a start point ? My guess is the sensor or related components.

thanks

cheers

Paul
zl1ajy




Reply | Threaded
Open this post in threaded view
|

Re: K3 PA Temp Reading Unstable

LY4OO
Hi
PA temp readings jumping from -110C to 110C, looks like troubles with
temperature sensor. Where to start dig?

Dan
LY4OO



--
Sent from: http://elecraft.365791.n2.nabble.com/
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: K3 PA Temp Reading Unstable

Roger-3
In reply to this post by paulb
Check Q1 (MJE182) and U1B (LM6482). Most likely U1 is bad..................

73/Roger - DL5RBW





______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html