Thanks for curing my builder's paranoia, Ron. That's all it was. :-)
Mike ab3ap
On Aug 3, 2010, at 11:18 PM, Ron D'Eau Claire wrote:
> ...It sounds like
> your meter is supplying enough voltage to start to turn some junctions "on"
> so they draw more current resulting in a lower resistance, then your meter
> switches ranges to one with less voltage and they again turn "off" and so
> on.
>
> Try using a manually-selected fixed range and see how it acts.
>
> Ron AC7AC
>
> -----Original Message-----
> [mailto:
[hidden email]] On Behalf Of Mike Markowski
> Sent: Tuesday, August 03, 2010 7:57 PM
> To: Elecraft
> Subject: [Elecraft] K3 assembly, resistance checks
>
> ...Of the 4 checks all are fine except for U12.
> Instead of getting a resistance reading on my digital meter, it never
> settles down. It cycles through a range of values up through the Mohm
> range...
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.html