K3 error message

classic Classic list List threaded Threaded
3 messages Options
Reply | Threaded
Open this post in threaded view
|

K3 error message

Mike Murray-4
After removing one filter from my subRx and moving the remaining filter
(2.8) to position #1, I'm now getting and ERR BP3 on start up.  Before I
open everything up again and remove the KRX3, SUBIN and SUBOUT boards and
reset everything as detailed in the manual, is there anything else I should
be doing to troubleshoot?  It's obviously a problem with the SubRx, but I
thought I was being ultra cautious during the disassembly/assembly process,
including use of static protection precautions.

Any suggestions will be appreciated!

73,
Mike - W0AG
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K3 error message

Don Wilhelm
Mike,

Since you moved the filters in the KRX3, you may want to go into the
CONFIG menu and tell it which filters for the KRX3 are installed and in
which slots.

73,
Do W3FPR

On 7/19/2016 8:06 PM, Mike Murray wrote:
> After removing one filter from my subRx and moving the remaining filter
> (2.8) to position #1, I'm now getting and ERR BP3 on start up.  Before I
> open everything up again and remove the KRX3, SUBIN and SUBOUT boards and
> reset everything as detailed in the manual, is there anything else I should
> be doing to troubleshoot?  It's obviously a problem with the SubRx, but I
> thought I was being ultra cautious during the disassembly/assembly process,
> including use of static protection precautions.
>
>

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K3 error message

Nr4c
Aren’t you supposed to have the filters in the sub receiver in the same slot as the main receiver?  I’m not saying that all filters in the main have to be in the sub, but any that are the same, shouldn’t they be in the sane slot?

…bc nr4c



> On Jul 20, 2016, at 8:15 PM, Don Wilhelm <[hidden email]> wrote:
>
> Mike,
>
> Since you moved the filters in the KRX3, you may want to go into the CONFIG menu and tell it which filters for the KRX3 are installed and in which slots.
>
> 73,
> Do W3FPR
>
> On 7/19/2016 8:06 PM, Mike Murray wrote:
>> After removing one filter from my subRx and moving the remaining filter
>> (2.8) to position #1, I'm now getting and ERR BP3 on start up.  Before I
>> open everything up again and remove the KRX3, SUBIN and SUBOUT boards and
>> reset everything as detailed in the manual, is there anything else I should
>> be doing to troubleshoot?  It's obviously a problem with the SubRx, but I
>> thought I was being ultra cautious during the disassembly/assembly process,
>> including use of static protection precautions.
>>
>>
>
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [hidden email]

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]