K3 synth / PLL faulty

Graham Kimbell
My K3 (old synths, ser1198) has for a few weeks had an intermittent
fault where the main rx synth loses lock. It seems ok when first
switched on but once warm (after maybe 30-60mins) the rx can die.  It
may seem ok but tuning around causes either complete failure or
intermittent failure on certain frequencies.

Attempts at recalibrating the synth using VCO MD results in an error,
typically ERR VCO 005.  If the fault is intermittent and I tap DISP to
view PLL volts, and then tune around the volts will be ok and then drop
to zero on frequencies where the synth dies.

I emailed elecraft support about this on 21 Jan but no response. I
raised a query on the tech support page on 25 Jan, no response yet.  It
looks like neither old synths nor new synths are available.

I'm about to pull the rig apart but has anyone any advice before I do
that. Thanks in advance

Graham
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: K3 synth / PLL faulty

Vic Rosenthal

The first thing to do when anything seems weird about the synths is to
check all of those little cables. Make they are all well-seated, and
push the connectors in and out a few times to clean off any corrosion.

73,
Victor, 4X6GP
Rehovot, Israel
CWops #5
Formerly K2VCO
https://www.qsl.net/k2vco/

On 31/01/2021 13:49, Graham Kimbell wrote:
> My K3 (old synths, ser1198) has for a few weeks had an intermittent
fault where the main rx synth loses lock. It seems ok when first
switched on but once warm (after maybe 30-60mins) the rx can die.  It
may seem ok but tuning around causes either complete failure or
intermittent failure on certain frequencies.
>
> Attempts at recalibrating the synth using VCO MD results in an
> error,
typically ERR VCO 005.  If the fault is intermittent and I tap DISP to
view PLL volts, and then tune around the volts will be ok and then drop
to zero on frequencies where the synth dies.
>
> I emailed elecraft support about this on 21 Jan but no response. I
raised a query on the tech support page on 25 Jan, no response yet.  It
looks like neither old synths nor new synths are available.
>
> I'm about to pull the rig apart but has anyone any advice before I
> do
that. Thanks in advance
>
> Graham
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]