K3 ver 03.79 and Palstar AT-AUTO

Mike K2MK
Hi Bill:

I think that problem occurs if you turn off the K3 before quitting the
Utility program. It's the quitting of the Utility program that initializes
the sequence to return the baud rate that you previously had the K3 set to.
It can't do it if the K3 is off.

73,
Mike K2MK

> FYI
>
> Just in case someone else has this same problem,   I loaded the latest K3
> firmware onto my rig and when the load was complete I found that my K3
> would no
> longer control the Palstar tuner.
 >
> It seems that the K3 Utility does not return the RS-232 port back to the
> original baud speed setting that was used before the down load when it is
> finished.  After I reset the RS-232 port speed back to the original 9600
> setting then the Palstar tuner started tracking again.
 >
> 73,
> Bill - K6WLM
> KX1, K2, K3-100k
 

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: K3 ver 03.79 and Palstar AT-AUTO

Dick Dievendorff
The K3 Utility changes speed before firmware load and restores speed  
right after firmware load. If you check the Verbose Logging View menu  
option and observe the Activity Log part of the firmware tab and  
perform a firmware load it should be clear when speed changes. In a  
subsequent version of K3 Utility now in Field Test I have added rig S/
N and RS 232 speed to the main window title bar to make the speed more  
obvious.

Dick, K6KR


Sent from my iPhone

On Mar 20, 2010, at 8:32 AM, "K2MK" <[hidden email]> wrote:

> Hi Bill:
>
> I think that problem occurs if you turn off the K3 before quitting the
> Utility program. It's the quitting of the Utility program that  
> initializes
> the sequence to return the baud rate that you previously had the K3  
> set to.
> It can't do it if the K3 is off.
>
> 73,
> Mike K2MK
>
>> FYI
>>
>> Just in case someone else has this same problem,   I loaded the  
>> latest K3
>> firmware onto my rig and when the load was complete I found that my  
>> K3
>> would no
>> longer control the Palstar tuner.
>>
>> It seems that the K3 Utility does not return the RS-232 port back  
>> to the
>> original baud speed setting that was used before the down load when  
>> it is
>> finished.  After I reset the RS-232 port speed back to the original  
>> 9600
>> setting then the Palstar tuner started tracking again.
>>
>> 73,
>> Bill - K6WLM
>> KX1, K2, K3-100k
>
>
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: K3 ver 03.79 and Palstar AT-AUTO

Mike K2MK
Hi Dick:

Thanks for the correction. I once experienced the problem that Bill described and I thought I had it figured out by my quitting the Utility program early. Obviously from your explanation this would not have caused Bill's problem.

73,
Mike K2MK

>
> The K3 Utility changes speed before firmware load and restores speed  
> right after firmware load. If you check the Verbose Logging View menu  
> option and observe the Activity Log part of the firmware tab and  
> perform a firmware load it should be clear when speed changes. In a  
> subsequent version of K3 Utility now in Field Test I have added rig S/
> N and RS 232 speed to the main window title bar to make the speed more  
> obvious.
>
> Dick, K6KR
>
>>
>>On Mar 20, 2010, at 8:32 AM, "K2MK" <k2mk@comcast.net> wrote:
>>
>> Hi Bill:
>>
>> I think that problem occurs if you turn off the K3 before quitting the
>> Utility program. It's the quitting of the Utility program that  
>> initializes
>> the sequence to return the baud rate that you previously had the K3  
>> set to.
>> It can't do it if the K3 is off.
>>
>> 73,
>> Mike K2MK
>>
>>> FYI
>>>
>>> Just in case someone else has this same problem,   I loaded the  
>>> latest K3
>>> firmware onto my rig and when the load was complete I found that my  
>>> K3
>>> would no
>>> longer control the Palstar tuner.
>>>
>>> It seems that the K3 Utility does not return the RS-232 port back  
>>> to the
>>> original baud speed setting that was used before the down load when  
>>> it is
>>> finished.  After I reset the RS-232 port speed back to the original  
>>> 9600
>> setting then the Palstar tuner started tracking again.
>>>
>>> 73,
>>> Bill - K6WLM
>>> KX1, K2, K3-100k