I am trying to program my first "Rotating Macro", where the PF1 Button
will set SPLIT+1 the first time it is pressed and held and it will UNSET SPLIT the second time it is pressed and held. I am basing this on the work by W8TN and LA3ZA, and others who have offered support here. I have had PF1 as SPLIT+1 and PF2 as SPLIT+5. They are saved in MACRO1 and MACRO2, respectively. I am trying to add MACRO3 and MACRO4 to CLEAR SPLIT and set to SPLIT+1 and SPLIT+5 again. I added the following to MACRO1 based on the Programmers reference: MN110;SWT20;SWH18;SWT14; #20 is listed as MACRO3, #18 is listed as PF1. But, the SPLIT part of the MACRO works, but the MACRO is not reprogrammed. So, little joy. When I execute the MACROs from K3 Utility, the reprogram things fine. But not when I hold the button. I hope I don't have to "add" these in CONFIG every time. That doesn't make sense. (100) 72, Byron ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
|
This is an RTFM problem.
I was confusing the KX3 Table with the K3 Table. When I used the proper values from the K3 Table, it worked perfectly. 73, Byron MACRO1-4: #11, 12, 13, 24 PF1-PF2: #45, 47 On 08/13/2015 08:14 PM, Byron Peebles wrote: > I am trying to program my first "Rotating Macro", where the PF1 Button > will set SPLIT+1 the first time it is pressed and held and it will > UNSET SPLIT the second time it is pressed and held. > > I am basing this on the work by W8TN and LA3ZA, and others who have > offered support here. > > I have had PF1 as SPLIT+1 and PF2 as SPLIT+5. They are saved in > MACRO1 and MACRO2, respectively. > > I am trying to add MACRO3 and MACRO4 to CLEAR SPLIT and set to SPLIT+1 > and SPLIT+5 again. > > I added the following to MACRO1 based on the Programmers reference: > > MN110;SWT20;SWH18;SWT14; > > #20 is listed as MACRO3, #18 is listed as PF1. > > But, the SPLIT part of the MACRO works, but the MACRO is not > reprogrammed. So, little joy. > > When I execute the MACROs from K3 Utility, the reprogram things fine. > But not when I hold the button. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
| Free forum by Nabble | Edit this page |