Attempting to set up K3s to do the following as per example in KE7X manual, p 212, under Macro Sequencing. His example is to program Macro 4 to change the AGC THR to 020 and Macro 5 to AGC 012 by using a Tap of M1. I do not wish to lose the ability to send cw with M1 so wish to use M4. Here is my coding for: Macro 4: MN074;MP020;SWT14;MN110;SWT27;SWH41;MN255; Macro 5: MN074;MP012;SWT14;MN110;SWT24;SWH41;MN255; When I test, via the Utility using Macro 4 it changes AGC to 020 confirmed by tapping M4. Same when selecting Macro 5, it changes AGC to 012, confirmed by tapping M4. However, repeated taps of M4 simply show the last selection, in case Macro 5. Also, after tapping M4 VFOs show 012 in A and AGC THR in B, until tapping M4 again. For contesting, this does not work for an efficient operation. So, what have I missed with my programming? How can I use M4 to cycle between 012 and 020 and recover my freq display? 73 Tom HP1/K6CT ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
|
Bear with me because this is from my memory. To the best of my knowledge you have to use the up button and down button to change values and cannot directly enter the value. As I recall Wayne stated it would be added to a future revision but apparently isn't present in the firmware you have which is likely the most recent.
This was a while back so I could be mistaken , however , this is exactly what I was doing at the time. On March 12, 2016 12:58:08 PM EST, [hidden email] wrote: > >Attempting to set up K3s to do the following as per example in KE7X >manual, p 212, under Macro Sequencing. His example is to program Macro >4 >to change the AGC THR to 020 and Macro 5 to AGC 012 by using a Tap of >M1. I do not wish to lose the ability to send cw with M1 so wish to >use >M4. > >Here is my coding for: >Macro 4: MN074;MP020;SWT14;MN110;SWT27;SWH41;MN255; > >Macro 5: MN074;MP012;SWT14;MN110;SWT24;SWH41;MN255; > >When I test, via the Utility using Macro 4 it changes AGC to 020 >confirmed by tapping M4. > >Same when selecting Macro 5, it changes AGC to 012, confirmed by >tapping >M4. > >However, repeated taps of M4 simply show the last selection, in case >Macro 5. > >Also, after tapping M4 VFOs show 012 in A and AGC THR in B, until >tapping M4 again. For contesting, this does not work for an efficient >operation. > >So, what have I missed with my programming? How can I use M4 to cycle >between 012 and 020 and recover my freq display? > >73 >Tom >HP1/K6CT >______________________________________________________________ >Elecraft mailing list >Home: http://mailman.qth.net/mailman/listinfo/elecraft >Help: http://mailman.qth.net/mmfaq.htm >Post: mailto:[hidden email] > >This list hosted by: http://www.qsl.net >Please help support this email list: http://www.qsl.net/donate.html >Message delivered to [hidden email] -- Sent from my Android device with K-9 Mail. Please excuse my brevity. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
| Free forum by Nabble | Edit this page |