KAT-500 Power Rating in Bypass

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

KAT-500 Power Rating in Bypass

Michael Tope
 From the KAT-500 owners manual the power ratings are as follows:

3—30 MHz 600W into 5 Ω to 500 Ω (10:1 SWR).
          1000W into 16 Ω to 150 Ω (3:1 SWR).

1.8-2.0 MHz 600 W into 10 Ω to 500 Ω (5:1 Low Impedance, 10:1 High
Impedance SWR).

Does anyone know what the power rating is for 160 meters when the tuner
is in bypass mode?

I would like to put my Alpha 87A in front of the KAT-500 and run the
KAT-500 in bypass mode on 160 meters at 1500 watts, and then at reduced
power on the other bands where I am actually using the tuner to match
the antenna. This is for a remote setup, so it is not convenient to
physically take the tuner out of amplifier's output path on 160 meters.

Thanks,

Mike W4EF...............



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]
Reply | Threaded
Open this post in threaded view
|

Re: KAT-500 Power Rating in Bypass

Jim Brown-10
Hi Mike,

I have a pair of KAT500's in my SO2R station. They're currently fed by a
pair of 87As, and before that, a pair of TenTec Titans. Both are legal
limit amps using the same tubes. My antennas are all close enough to
resonance that I can use the tuners in bypass mode and use the
amplifier's output network to keep the tubes happy.  I have an LP100A
inline with both amps, and, for legal limit contests, I keep the power
right there. The KAT500s are happy with that arrangement. They were NOT
happy in Man mode above about 1 kW, and the level at which they got
unhappy was reduced increased mismatch.

73, Jim K9YC

On 1/25/2018 10:31 PM, Michael Tope wrote:
> Does anyone know what the power rating is for 160 meters when the
> tuner is in bypass mode?


______________________________________________________________