[KAT] Circuit operation question

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

[KAT] Circuit operation question

dean
Hi all,
    I have a question about the circuit of the KAT1.  According to the
manual, page 12,  if the circuit is put into either the ATU CLS or CLP
modes, all the relays are RESET to all L=0 and all C=0.  No problem
here.  Now if you go to the circuit schematic at the end of the manual,
you will see a note at the bottom left that saysa all relays are shown
in the reset position.  Here is my problem and question; I agree that
the lower relays for the capacitors are all in the so-called RESET
postion as all caps are out of the circuit and therefore all caps are
set to C0.  However, tracing out the 4 inductor relays shows that they
are ALL IN the circuit [all inductors (5uH total)connected in series] in
the shown RESET position.  To me, being set to L=0 means that the relays
should be shorted out and the KAT1's path from P2 pins 2 and 10 should
be direct or straight through.  I believe that those 4 inductors are
really shown in the IN position not the RESET position as declared on
the schematic.  Am I correct or just don't understand?

Thanks,
Dean
K6DDJ
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: [KAT] Circuit operation question

Don Wilhelm-4
Dean,

I never noticed before, but you are correct.  The schematic does agree
with the board layout too, so the firmware is apparently moving the
relays to the set position to bypass the inductors.

What I can say is that it does work properly!

73,
Don W3FPR

On 11/26/2012 7:45 AM, [hidden email] wrote:

> Hi all,
>      I have a question about the circuit of the KAT1.  According to the
> manual, page 12,  if the circuit is put into either the ATU CLS or CLP
> modes, all the relays are RESET to all L=0 and all C=0.  No problem
> here.  Now if you go to the circuit schematic at the end of the manual,
> you will see a note at the bottom left that saysa all relays are shown
> in the reset position.  Here is my problem and question; I agree that
> the lower relays for the capacitors are all in the so-called RESET
> postion as all caps are out of the circuit and therefore all caps are
> set to C0.  However, tracing out the 4 inductor relays shows that they
> are ALL IN the circuit [all inductors (5uH total)connected in series] in
> the shown RESET position.  To me, being set to L=0 means that the relays
> should be shorted out and the KAT1's path from P2 pins 2 and 10 should
> be direct or straight through.  I believe that those 4 inductors are
> really shown in the IN position not the RESET position as declared on
> the schematic.  Am I correct or just don't understand?
>
> Thanks,
> Dean
> K6DDJ
>

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html