KIO2 Daisy Chaining

classic Classic list List threaded Threaded
3 messages Options
Reply | Threaded
Open this post in threaded view
|

KIO2 Daisy Chaining

JT Croteau
This may seem like a stupid question but I thought I'd ask before I
warm up the slobbering iron.

I'm in the process of building my first Elecraft transverter.  I'm
going to need to modify my existing serial cable for interfacing it to
the K2.  I'm ultimately planning on interfacing all four transverters
along with a KPA100 w/ KAT100 mounted together in an EC2.  Can I go
ahead and make up the daisy chain KIO2 cable now with all options in
mind?  Will everything work properly with some of the connectors not
connected to anything?   I'd much rather build one cable now than
having to keep modifying the same cable as I add options.

Thanks

--
JT Croteau, N1ESE - Manchester, NH
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: KIO2 Daisy Chaining

Don Wilhelm-4
JT,

Yes, you can build up the entire daisy chain for the transverters.  That
is what a 'Daisy chain' implies, one connector is just as good as any
other - the signals are sent to all the 'listeners'.  If you experience
any problems, it will be with the total cable length and the
signalling/response times required for the AUXBUS signalling.  Keep the
total cable length to less than 6 feet for reliable operation - actually
tyr to keep the length to the minimum feasible.

73,
Don W3FPR

JT Croteau wrote:

> This may seem like a stupid question but I thought I'd ask before I
> warm up the slobbering iron.
>
> I'm in the process of building my first Elecraft transverter.  I'm
> going to need to modify my existing serial cable for interfacing it to
> the K2.  I'm ultimately planning on interfacing all four transverters
> along with a KPA100 w/ KAT100 mounted together in an EC2.  Can I go
> ahead and make up the daisy chain KIO2 cable now with all options in
> mind?  Will everything work properly with some of the connectors not
> connected to anything?   I'd much rather build one cable now than
> having to keep modifying the same cable as I add options.
>
> Thanks
>
>  
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: KIO2 Daisy Chaining

JT Croteau
On 9/26/07, Don Wilhelm <[hidden email]> wrote:
> Keep the total cable length to less than 6 feet for reliable
> operation - actually try to keep the length to the minimum feasible.

Thanks Don, I hear ya.  My longest run will be for PC interfacing
which doesn't use the AUXBUS.  I was .planning on ~16" ea. for the
KPA100 run and the first XV and then 10" to each additional XV for a
total of 62".  The XV's will be stacked on top of each other so I
could likely go even shorter but the cables become harder to work
with, for me anyway, when they get much shorter.

--
JT Croteau, N1ESE - Manchester, NH
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com