KPA fan query

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

KPA fan query

Vic@VicsFloridaVilla.com
Gangue,

My first post for a very long time .......

I am finally completing the build of my KPA100.....just  one little
snagette.

Initial tests with power to the K2 only (no PA module power applied) and pa
connected to the K2 with the ribbon cable  all seems well  - except  the fan
stays on all the time.

Can anyone confirm whether  this normal at this stage ?  The manual does not
mention this.

Many thanks,

ic  GW4JUN

K2 1926

ps Didn't like cutting the pcb trace in the control board mod - scary !!!!
Worked OK though ....



_________________________________________________________________
Holidaying in Orlando Florida ?
Why not rent our luxurious villa
just 12 minutes from Disney and
close to all attractions and numerous golf courses.
Telephone Vic on +44 (0)1352 780550
e mail for colour brochure to [hidden email]
or visit our website   www.VicsFloridaVilla.com
_________________________________________________

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: KPA fan query

Brian Mury-3
On Sat, 2005-07-02 at 16:42 +0100, [hidden email] wrote:
> the fan stays on all the time.

Did you do the temperature calibration step?

--
73, Brian
VE7NGR
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com