Gangue,
My first post for a very long time .......
I am finally completing the build of my KPA100.....just one little
snagette.
Initial tests with power to the K2 only (no PA module power applied) and pa
connected to the K2 with the ribbon cable all seems well - except the fan
stays on all the time.
Can anyone confirm whether this normal at this stage ? The manual does not
mention this.
Many thanks,
ic GW4JUN
K2 1926
ps Didn't like cutting the pcb trace in the control board mod - scary !!!!
Worked OK though ....
_________________________________________________________________
Holidaying in Orlando Florida ?
Why not rent our luxurious villa
just 12 minutes from Disney and
close to all attractions and numerous golf courses.
Telephone Vic on +44 (0)1352 780550
e mail for colour brochure to
[hidden email]
or visit our website www.VicsFloridaVilla.com
_________________________________________________
_______________________________________________
Elecraft mailing list
Post to:
[hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help:
http://mailman.qth.net/subscribers.htmElecraft web page:
http://www.elecraft.com