As I near completion of the 100 W stage, I ran through the Alignment and
Installation resistance checks on p. 41 of the KPA100 manual. They all
come out as expected except that the Q1 & Q2 base readings are below the
given resistance range of 12-16 ohms. My readings are 11.3 ohms for
each. Is this far enough out of range to be a worry?
Thanks,
Mike AB3AP
Avondale, PA
_______________________________________________
Elecraft mailing list
Post to:
[hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help:
http://mailman.qth.net/subscribers.htmElecraft web page:
http://www.elecraft.com