I was having similar problems with my KPA500 on 6 meters. I originally
had it set up for 240 volt operation. Changing it over to 120 volt
operation seems to have helped quite a bit. Also I changed transformer
taps because the HV pulled a little low on TX. I still get a fault now
and then but believe it may have to do with some SWR on my 6 meter antenna.
Mike
KI0HA
On 3/30/2015 13:55, Terry Burkholder wrote:
> I have a new KPA500. It works well on all HF bands but on six meters
> with any more than 280 watts out I get a "PA DISS" fault. This is into
> a 500 watt dummy load. External Diawa CN 801 power meter power reading
> agrees with the KPA500 wattmeter.
>
> At 280 Watts out the drive, from the K3, on six meters is 20 Watts, HV
> 74 volts no load, 60 volts loaded, current 13.6 A SWR 1:1
>
> Any suggestions?
>
> Thanks, Terry N4TB
>