I suggest you run the TX Gain
Calibration procedure on the K3. That
worked for me.
73, Ken K3IU
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
On 12/27/2012 8:24 PM, Bill Hammond wrote:
> Seasons Greetings Ellecrafters,
>
> "KPA500 faults on first dit at times"
>
> It doesn't happen all the time and I can't pin down the sequence of events when it happens, the last time was after a band QSY after clicking on a spot in my logging software. I am wondering if others have had issue or have solved the problem. The fault on the KPA500 is too much drive. I have the drive adjusted per band and none above 32 watts. It resets quickly and all is well after the initial fault. It usually happens once or twice a day.
>
> After bringing the amplifier back on line, all is well. It just scares me when it happens :)
>