Hello Group,
There are Method 1 and Method 2 for frequency calibration on P.50 of the K3 operation manual. Has the calibration specific for KTCXO3 implemented? Do I miss anything? Or, simply, is there any frequency calibration needed for KTCXO3 (apart from data entry in K3 Utility) ? TNX & 73, Johnny VR2XMC ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
Hello Johnny.
There is still no implementation of the temp vs. frequency data for the KTCXO-3. You can enter the data into the Utility program, but it is not yet used for anything. The KTCXO-3 does have better stability than the stock reference oscillator, and in may cases meets the 0.5 ppm spec without the implementation of the temp data. You still need to perform frequency calibration using either method 1 or 2 from the manual. Or, with the new K3EXREF board, the correction is done for you, if you are using a high stability external reference. This works very well here. I hope this info helps. 73, Bruce, N1RX > There are Method 1 and Method 2 for frequency calibration on P.50 of the K3 operation manual. Has the calibration > specific for KTCXO3 implemented? Do I miss anything? Or, simply, is there any frequency calibration needed for > KTCXO3 (apart from data entry in K3 > Utility) > Johnny VR2XMC ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
Thanks, Bruce
Sent from my iPhone 4 "Bruce Beford" <[hidden email]> 於 2011年6月5日 下午7:34 寫道: > Hello Johnny. > > There is still no implementation of the temp vs. frequency data for the > KTCXO-3. You can enter the data into the Utility program, but it is not yet > used for anything. The KTCXO-3 does have better stability than the stock > reference oscillator, and in may cases meets the 0.5 ppm spec without the > implementation of the temp data. You still need to perform frequency > calibration using either method 1 or 2 from the manual. Or, with the new > K3EXREF board, the correction is done for you, if you are using a high > stability external reference. This works very well here. > > I hope this info helps. > > 73, > Bruce, N1RX > > >> There are Method 1 and Method 2 for frequency calibration on P.50 of the > K3 operation manual. Has the calibration >> specific for KTCXO3 implemented? Do I miss anything? Or, simply, is > there any frequency calibration needed for >> KTCXO3 (apart from data entry in K3 > Utility) >> Johnny VR2XMC > > > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
Free forum by Nabble | Edit this page |