Bob,
After experimenting with my macros, you are correct. The first command in my macro string is MD6; and AGC is off after that. Just issuing MD6; in the KX3 Utility turns off AGC. To turn it back on, I put GT004; into the next macro string which turns AGC-S on.
Actually, just setting MD2; turns AGC back on either FAST or SLOW depending on the last known setting which means I can just take GT004; out of my second macro string.
Thanks,
Joel - W4JBB