KX3 anormal output voltage reading

Jean-François | VA2SS
CONTENTS DELETED
The author has deleted this message.
Reply | Threaded
Open this post in threaded view
|

Re: KX3 anormal output voltage reading

Don Wilhelm-4
J-F,

Do you have an early KX3 that was a kit?  If so, the Transmit nulling
procedure may not have been done at the factory as it is now done for
KX3 kits as well as factory builds.  Check page 33 of the manual that
shipped with your KX3.  If you have that procedure listed in the manual,
try to do the steps, I believe it has a good possibility to solve your
problem.

73,
Don W3FPR

On 1/26/2014 7:49 PM, VA2SS wrote:

> I found my problem with my recent KXPA100 purchase.
>
> My KX3 always have voltage reading on the antenna port even if the power set
> is set to 0.
>
> I found this when pushing the MIC PTT only. I am able to read approximately
> 9V on the Elecraft DL1. The KX3 always show RF bar on the display of about
> 3W !!!!
>
> Even without the mic, I still have a reading. Power set from 0 to Max always
> gave me in SSB a strange reading of 9V without talking.
>
> This seems to be RF or something.
>
> I removed every options that was installed : roofing filter, antenna tuner,
> battery charger.
>
> I also removed the RF board and instead of using the Elecraft BNC with the
> filter & toroïd , I connect directly the dummy load to the block header on
> the RF board inside the KX3.
>
> I still have a 9V or so reading when pushing the PTT in SSB without talking.
>
> At this moment, this prevent me of using my KXPA100.
>
> I hope someone could help.
>
> 73
>
>

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: KX3 anormal output voltage reading

Jean-François | VA2SS
CONTENTS DELETED
The author has deleted this message.
Reply | Threaded
Open this post in threaded view
|

Re: KX3 anormal output voltage reading

Don Wilhelm-4
Jean-Francios,

I believe that means you should email [hidden email] for further
assistance.
Try doing the TX Gain calibration before attempting the TX Carrier
Balance.  It seems you have a failure in the TX Gain calibration, or at
least the TX carrier balance procedure thinks there is a problem.

73,
Don W3FPR
On 1/26/2014 8:31 PM, JEAN-FRANCOIS MENARD wrote:

> Hi Don,
>
> I did the procedure on page 33.
>
> On the 4W test, these bands failed with the error code ERR TXG D=0000
>
> Bands that failed are 60m, 40m, 20m, 17m, 12m
>
> On the 6W test, all bands passed the test.
>