Hi Folks. Sorry if this has been asked/explained before.
I have installed the KXBC3 NiMH Battery Charger module. I am using 2300mh/h NiMH AA cells. I have plugged a bench power supply with voltage/amp meters so I can check what is going on. My cells were not empty, so I have chosen 4 hours charge. I set the PS to 14VDC. The PS amp meter reads 390mA during the charging, which is about 190mA for the rig RX drain plus 200mA for the batteries. So far so good. I monitor the elapsed time in the MENU/BAT CHG and the BAT voltage, which goes up to 11.7V. After 1 hour and so, the elapsed time chronometer stops. The PS amp meter reads only 190mA. So it seems that the charger stopped charging. That is in-line with the fact that the battery was somewhat charged. I go to MENU/BAT CHG and turn the charger OFF. I also unplug the power supply. The battery voltage drops to 11V on the screen. In any phase of the process I got no error message. Is this an expected behavior ? I have not seen anywhere an explanation of what happens if the battery is totally charged. Is the counter supposed to stop, or it should keep on sending charge to the battery until the total programmed time elapses?. Any input is appreciated. Thanks -- Fred - PY2XB *Other Calls*: PY2FXH, PY2FXH/W2, PY2XB/0, F/PY2XB, ZX2XB, PT7BXB, PY2XB/PY0F, PQ0F, VP5/PY2XB, PW2IO (SA-071), ZX8W (SA-060), PY2XB/1 (SA-029), 8P9XB, PQ8XB (SA-045), ZX2S (SA-028); W4/PY2XB, 3D2XB *Team member*: PW2M (SA-071), PX8J (SA-041), T30PY/T30SIX, PT0S ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
|
Fred,
Most likely the battery temperature got up to 45 degrees C and charging was suspended until they cooled to 40 C. Normally a message should appearwhen that happens. 73, Rich AC7MA On 02/01/2013 12:02 PM, Fred Carvalho wrote: > Hi Folks. Sorry if this has been asked/explained before. > I have installed the KXBC3 NiMH Battery Charger module. I am using 2300mh/h > NiMH AA cells. > I have plugged a bench power supply with voltage/amp meters so I can check > what is going on. My cells were not empty, so I have chosen 4 hours charge. > I set the PS to 14VDC. The PS amp meter reads 390mA during the charging, > which is about 190mA for the rig RX drain plus 200mA for the batteries. So > far so good. > I monitor the elapsed time in the MENU/BAT CHG and the BAT voltage, which > goes up to 11.7V. After 1 hour and so, the elapsed time chronometer stops. > The PS amp meter reads only 190mA. So it seems that the charger stopped > charging. That is in-line with the fact that the battery was somewhat > charged. > I go to MENU/BAT CHG and turn the charger OFF. I also unplug the power > supply. The battery voltage drops to 11V on the screen. > In any phase of the process I got no error message. > > Is this an expected behavior ? I have not seen anywhere an explanation of > what happens if the battery is totally charged. Is the counter supposed to > stop, or it should keep on sending charge to the battery until the total > programmed time elapses?. > > Any input is appreciated. Thanks > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
| Free forum by Nabble | Edit this page |