Hi Dave,
I ran my new KXPA100 with my KX3 for a lengthy rag-chew using Olivia
16/500 on 60m at 30W power, and after about 45 minutes of QSO time, I
hit the PA temp limit.
I added some USB powered fans (just taped together and sat on top of the
amp's heatsink with rubber feet), and used a USB power switch to turn
them off and on as required.
I noted the following results.
Firstly a 5 minute transmission ...
60m, tx into dummy load, Olivia 16-500, 25W Fans On
Start temp 27C, Peak Temp 37C at 05:09.42, End temp 27C @ 09:47.98
Then a 10 minute transmission ...
60m, tx into dummy load, Olivia 16-500, 25W Fans On
Start temp 26C, Peak Temp 38C @ 10:02.57. End temp 25C @ 17:37.95
So, I don't have any info for you regarding running digimodes at 100W,
but for long transmissions or high duty cycle work, you may well need
extra cooling at 25-30W.
Cheers, 73
Darren, G0hWW
On 13/05/15 18:04, David Patino wrote: