There was some chatter about this issue earlier in the year but did not see any clear resolution. Like what others were seeing, the utility program successfully completes 5 and 50 watt calibrations but "settles on 0.1mw" when performing the 1 milliwatt cal; i.e., fails to achieve 1.0mw.
With the 5w and 50w calibration process, the power is automatically adjusted by the utility program to achieve the correct power level. However, the power does NOT automatically adjust when running the 1 mw cal. I can fool the program by manually adjusting power to 1.00 mw for each band but suppose that defeats the purpose. There is a 50 ohm DL on the XVTR out in accordance with directions. Yes... Jumpers W1 and W2 were cut flush with the board. I have the latest FW in the K3. What's the next step? Thanks & 73, John K1JD SN #071 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
|
There was a change in K3 firmware around version 4.43 where we had to use a
different PC command to ask for 1 milliwatt out. The current K3 Utility uses different PC commands to request 1 milliwatt depending on MCU revisions. If you're using an older K3 Utility you might see 0.1 milliwatt requested. 73 de Dick, K6KR -----Original Message----- From: [hidden email] [mailto:[hidden email]] On Behalf Of JohnDePrimo Sent: Wednesday, January 09, 2013 1:42 PM To: [hidden email] Subject: [Elecraft] KXV3A Utility Program 1 milliwatt calibration failure There was some chatter about this issue earlier in the year but did not see any clear resolution. Like what others were seeing, the utility program successfully completes 5 and 50 watt calibrations but "settles on 0.1mw" when performing the 1 milliwatt cal; i.e., fails to achieve 1.0mw. With the 5w and 50w calibration process, the power is automatically adjusted by the utility program to achieve the correct power level. However, the power does NOT automatically adjust when running the 1 mw cal. I can fool the program by manually adjusting power to 1.00 mw for each band but suppose that defeats the purpose. There is a 50 ohm DL on the XVTR out in accordance with directions. Yes... Jumpers W1 and W2 were cut flush with the board. I have the latest FW in the K3. What's the next step? Thanks & 73, John K1JD SN #071 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
|
Hi Dick,
That did it, thanks. My utility program was not THAT old, but old enough - hi. 73, John K1JD Santa Fe, NM On Jan 9, 2013, at 2:56 PM, "Dick Dievendorff" <[hidden email]> wrote: > There was a change in K3 firmware around version 4.43 where we had to use a > different PC command to ask for 1 milliwatt out. The current K3 Utility uses > different PC commands to request 1 milliwatt depending on MCU revisions. > > If you're using an older K3 Utility you might see 0.1 milliwatt requested. > > 73 de Dick, K6KR > > > > -----Original Message----- > From: [hidden email] > [mailto:[hidden email]] On Behalf Of JohnDePrimo > Sent: Wednesday, January 09, 2013 1:42 PM > To: [hidden email] > Subject: [Elecraft] KXV3A Utility Program 1 milliwatt calibration failure > > There was some chatter about this issue earlier in the year but did not see > any clear resolution. Like what others were seeing, the utility program > successfully completes 5 and 50 watt calibrations but "settles on 0.1mw" > when performing the 1 milliwatt cal; i.e., fails to achieve 1.0mw. > > With the 5w and 50w calibration process, the power is automatically adjusted > by the utility program to achieve the correct power level. However, the > power does NOT automatically adjust when running the 1 mw cal. I can fool > the program by manually adjusting power to 1.00 mw for each band but suppose > that defeats the purpose. > > There is a 50 ohm DL on the XVTR out in accordance with directions. Yes... > Jumpers W1 and W2 were cut flush with the board. I have the latest FW in the > K3. What's the next step? > > Thanks & 73, > John K1JD > SN #071 > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
| Free forum by Nabble | Edit this page |