My PC to KPA100 communication suddenly failed. Checked the cabling and  
did some initial tracing from J1 to U4. Seems ok incl. RFC:s. I found  
deviating voltages on U4 pins:
2 -5,5
3 -10,7
4,5,6 -5,5
7,8 -10,7

with remaining U4 pin readings ok.

Then tried to find the 16293 kHz signal on my SW receiver but couldnĀ“t  
hear it. I however find  -75 V at the end of the diode chain.....so is  
the HV xtal oscillator at foult or not? Any suggestion on what to do  
next is much appreciated! Thanks, 73, Per  SM0WRA .