Thanks for all the quick replies.
The data is at
http://www.hascorelays.com/electro_klt_series.asp.
The dielectric strength between open contacts is specified at 750VAC
(50/60Hz). Guessing that the dielectric is air and air has a breakdown
voltage of about 3KV/mm that equates to a contact spacing of about 0.25 mm.
Wow that seems very small. Have I figured this wrong?
Darrell
On July 6, 2006 03:09 pm,
[hidden email] wrote:
> KLT1C12DC12 made by Hasco
>
> Michael
> N2ZDB
> _______________________________________________
--
Darrell Bellerive
Amateur Radio Stations VA7TO and VE7CLA
Grand Forks, British Columbia, Canada
_______________________________________________
Elecraft mailing list
Post to:
[hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help:
http://mailman.qth.net/subscribers.htmElecraft web page:
http://www.elecraft.com