Hi Jim:
>I probably killed your download volume for the month, Tom. I >apologize. I am new to owning my own server space (http://www.al7fs.us/) >and had not thought about the ramifications of downloading material. When >I got the END of the page, the heathkit section mentioned the limit and >massive guilt hit me hard. NO PROBLEM PAL! I don't think I've had much 'traffic' this month, so it was no biggie at all! >Never-the-less, these links did not work. I thought you would like to know. > >K2 - Component Placement - Searchable PDF (690kB) > >KR5L CW LED Tuning Indicator PDF (150 kB) > >SOLDERING TIPS, Useful Soldering Hints PDF (285 kB) > >SB-220 Schematic, 1-pg. 11" x 14" in size PDF (207 kB) (revised 10-28-2002) >SB-220 Schematic, 2-pg. 8.5" x 11" in size PDF (249kB) (revised 10-28-2002) Thanks(!) to all the folks who kindly advised me of the numerous busted links (it WAS 1 am when I finally got things moved over, I was about 95% asleep at tht time), I think I've now fixed ALL of the busted links. Guess time will tell (again). Please try once more, and I sincerely apologize for your wasted effort previously. My new web site have such horrendously gigantic upload/download quotas that I don't think I'll EVER exceed them, so have at it! 73, Tom N0SS _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
Well we are moving right along. Just got to the Second aliignment and test
section na dthe 4 mhz osc calibration went fine. The PLL reference range test looked good and the range was right in the middle of the road. But when I plugged the freq probe in TP1 and did a cal factor to check the VCO is says 000000. I am going though all my assembly now to make sure I did not miss anything. Can anyone think of any common mistakes I might be overlooking? Thanks and 73, Rich _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
Hi
The most common problem is with the is T5. Make sure it is wound right and the leads are stripped properly. Don Brown KD5NDB ----- Original Message ----- From: Rich McCabe<mailto:[hidden email]> To: Elecraft Reflector<mailto:[hidden email]> Sent: Sunday, August 22, 2004 7:42 PM Subject: [Elecraft] Alignment and test part II Well we are moving right along. Just got to the Second aliignment and test section na dthe 4 mhz osc calibration went fine. The PLL reference range test looked good and the range was right in the middle of the road. But when I plugged the freq probe in TP1 and did a cal factor to check the VCO is says 000000. I am going though all my assembly now to make sure I did not miss anything. Can anyone think of any common mistakes I might be overlooking? Thanks and 73, Rich _______________________________________________ Elecraft mailing list Post to: [hidden email]<mailto:[hidden email]> You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft<http://mailman.qth.net/mailman/listinfo/elecraft> Help: http://mailman.qth.net/subscribers.htm<http://mailman.qth.net/subscribershtm> Elecraft web page: http://www.elecraft.com<http://www.elecraft.com/> _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
In reply to this post by Rich McCabe
Rich,
Be certain the frequency counter probe is still working by plugging it into TP3 again, then -- Check T5 to be certain you have well tinned leads and good solder joints. Then check the orientation of D13. Check soldering on all components shown in the schematic VFO section (RF board sheet 1 of 4), and while you are at it, check the components for proper values. If all the above is correct, the VFO should oscillate (and produce an indication on the frequency counter). Try the probe on pin 3 of U3 to see if you get anything there, if so, you should have a good frequency reading at TP1 unless U3 is not working correctly. 73, Don W3FPR ----- Original Message ----- > Well we are moving right along. Just got to the Second aliignment and test > section na dthe 4 mhz osc calibration went fine. The PLL reference range > test looked good and the range was right in the middle of the road. But when > I plugged the freq probe in TP1 and did a cal factor to check the VCO is > says 000000. > > I am going though all my assembly now to make sure I did not miss anything. > Can anyone think of any common mistakes I might be overlooking? > _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
This group is awesome :)
Yea I was being stupid !! Was so particular about winding the torroids and then when I installed T5 reversed it. So now I have a signal.. Thanks Don, Don and Tom ! Rich kd0zv ----- Original Message ----- From: "Don Wilhelm" <[hidden email]> To: "Rich McCabe" <[hidden email]>; "Elecraft Reflector" <[hidden email]> Sent: Sunday, August 22, 2004 8:36 PM Subject: Re: [Elecraft] Alignment and test part II > Rich, > > Be certain the frequency counter probe is still working by plugging it into > TP3 again, then -- > Check T5 to be certain you have well tinned leads and good solder joints. > Then check the orientation of D13. Check soldering on all components shown > in the schematic VFO section (RF board sheet 1 of 4), and while you are at > it, check the components for proper values. > > If all the above is correct, the VFO should oscillate (and produce an > indication on the frequency counter). Try the probe on pin 3 of U3 to see > if you get anything there, if so, you should have a good frequency reading > at TP1 unless U3 is not working correctly. > > 73, > Don W3FPR > > ----- Original Message ----- > > > Well we are moving right along. Just got to the Second aliignment and > test > > section na dthe 4 mhz osc calibration went fine. The PLL reference range > > test looked good and the range was right in the middle of the road. But > when > > I plugged the freq probe in TP1 and did a cal factor to check the VCO is > > says 000000. > > > > I am going though all my assembly now to make sure I did not miss > anything. > > Can anyone think of any common mistakes I might be overlooking? > > > > > _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |