Any progress in this area? I'm experiencing the same problem.
KPA500 s/n 468 fw v1.11 with BAND CHG set to STBY
K3 s/n 495 fw v4.42 with PWR SET set to PER BAND
Works correctly when using band change up/down buttons on K3 but when
using band change buttons on KPA500 the power setting for OPER remains
in effect after the change - the STBY power setting is not recalled.
Bob NW8L
This _was_ fixed in the V1.11 firmware. I will be contacting you off-list to
get more details to determine why it may not be working in your setup.
Jack Brindle, W6FB
Elecraft Engineering
On Sep 25, 2011, at 11:01 AM, Richard Squire - HB9ANM wrote:
> On July 1, I wrote:
> "When BAND CHG is set to STBY (which I prefer in order to avoid tuning my
> dipole on the new band with 400 W instead of 20 W by mistake!), the KPA500
> does go into STBY when changing bands but the K3 keeps the lower power
> setting and does not return to 100 W. This does not happen if BAND CHG is
> set to NOR."
>
> This was supposed to be a timing problem to be resolved with the next FW
> release but FW 1.11 didn't solve it. Any one else noticed this?
> Not a big issue but I'd like to go for BAND CHG = STBY...
> Anyway, the KPA500 is joy to use.
>
> 73
>
> -----
> Richard - HB9ANM