Re: Slope Macro Settings

classic Classic list List threaded Threaded
1 message Options
Reply | Threaded
Open this post in threaded view
|

Re: Slope Macro Settings

Cady, Fred-2
Hi Dan,

You can go into the AGC SLP menu and then do a sequence of UP; and DN; commands to arrive at your final value.  The strategy for these types of macros is to drive the parameter to one end, e.g. 15 UP; commands set SLP=15 and then 5 DN; changes it back to 10, if that's the value you want.


Cheers,

Fred KE7X

________________________________
From: Dan Atchison <[hidden email]>
Sent: Thursday, February 23, 2017 8:30 AM
To: Cady, Fred
Subject: Slope Macro Settings

Hi Fred:

You wrote:
"BTW, it is easy to make macros to switch between different THR/SLP values for different operating conditions."

I see how you can write a macro to set Threshold settings, but how is that done with Slope settings?

Thanks,
Dan -- N3ND




______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]