Hi Dan,
You can go into the AGC SLP menu and then do a sequence of UP; and DN; commands to arrive at your final value. The strategy for these types of macros is to drive the parameter to one end, e.g. 15 UP; commands set SLP=15 and then 5 DN; changes it back to 10, if that's the value you want.
Cheers,
Fred KE7X
________________________________
From: Dan Atchison <
[hidden email]>
Sent: Thursday, February 23, 2017 8:30 AM
To: Cady, Fred
Subject: Slope Macro Settings
Hi Fred:
You wrote:
"BTW, it is easy to make macros to switch between different THR/SLP values for different operating conditions."
I see how you can write a macro to set Threshold settings, but how is that done with Slope settings?
Thanks,
Dan -- N3ND
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.htmlMessage delivered to