Remote KPA500 Via Moxa - On/Off Switch via S/W not stable

classic Classic list List threaded Threaded
4 messages Options
Reply | Threaded
Open this post in threaded view
|

Remote KPA500 Via Moxa - On/Off Switch via S/W not stable

4Z4OQ
Hi
My Set up is TS-480 via remote rig and controlling KPA500 & KAT500 via Moxa rs232 Server port 1 38400bit/s. My issue is as follows:-

1. I can connect to the Amplifier via KPA500 utility, can change bands, can switch from stby to oper but sometimes times cant change the power switch to off mode.
2. In amplifier is on stby (ON) mode and by mistake close the utility SW, when I reopen the software the o/off status is off, but I know the amplifier is On

Any ideas..?
Reply | Threaded
Open this post in threaded view
|

Re: Remote KPA500 Via Moxa - On/Off Switch via S/W not stable

Dick Dievendorff
I've just done a little tweaking to the KPA Utility's timing.  After the
power off command is issued it takes a little while before the KPA500 is
responsive to any other serial commands.  The KPA Utility doesn't wait quite
long enough.

I'll try to get this early Beta version on to an FTP site for you to test.

73 de Dick, K6KR


-----Original Message-----
From: [hidden email]
[mailto:[hidden email]] On Behalf Of 4Z4OQ
Sent: Friday, March 22, 2013 3:22 PM
To: [hidden email]
Subject: [Elecraft] Remote KPA500 Via Moxa - On/Off Switch via S/W not
stable

Hi
My Set up is TS-480 via remote rig and controlling KPA500 & KAT500 via Moxa
rs232 Server port 1 38400bit/s. My issue is as follows:-

1. I can connect to the Amplifier via KPA500 utility, can change bands,
can
switch from stby to oper but sometimes times cant change the power switch to
off mode.
2. In amplifier is on stby (ON) mode and by mistake close the utility
SW,
when I reopen the software the o/off status is off, but I know the amplifier
is On

Any ideas..?




--
View this message in context:
http://elecraft.365791.n2.nabble.com/Remote-KPA500-Via-Moxa-On-Off-Switch-vi
a-S-W-not-stable-tp7571721.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: Remote KPA500 Via Moxa - On/Off Switch via S/W not stable

Doug Joyce
In reply to this post by 4Z4OQ
Hi Viz:  Just a thought

When you reopen the KPAUtil software in step 2, go to the "Port" tab and
Test Communications.  When it has set itself up (usually at 38400) and says
things are ok, then go to the "Operate" tab.  It should now portray the
actual operating conditions - I have to do this on occasion when things get
out of sync.

Hope this helps.

73,  Doug  VE3MV

----- Original Message -----
From: "4Z4OQ" <[hidden email]>
To: <[hidden email]>
Sent: Friday, March 22, 2013 6:22 PM
Subject: [Elecraft] Remote KPA500 Via Moxa - On/Off Switch via S/W not
stable


> Hi
> My Set up is TS-480 via remote rig and controlling KPA500 & KAT500 via
> Moxa
> rs232 Server port 1 38400bit/s. My issue is as follows:-
>
> 1. I can connect to the Amplifier via KPA500 utility, can change bands,
> can
> switch from stby to oper but sometimes times cant change the power switch
> to
> off mode.
> 2. In amplifier is on stby (ON) mode and by mistake close the utility SW,
> when I reopen the software the o/off status is off, but I know the
> amplifier
> is On
>
> Any ideas..?
>
>
>
>
> --
> View this message in context:
> http://elecraft.365791.n2.nabble.com/Remote-KPA500-Via-Moxa-On-Off-Switch-via-S-W-not-stable-tp7571721.html
> Sent from the Elecraft mailing list archive at Nabble.com.
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
>

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: Remote KPA500 Via Moxa - On/Off Switch via S/W not stable

mcduffie
In reply to this post by Dick Dievendorff
On Fri, 22 Mar 2013 15:54:21 -0700, Dick Dievendorff wrote:

> I've just done a little tweaking to the KPA Utility's timing.  After the
> power off command is issued it takes a little while before the KPA500 is
> responsive to any other serial commands.  The KPA Utility doesn't wait quite
> long enough.

Dick,

Any word on a change to allow the TS-590 band information to be properly read by
the KPA when using memories?  As previously reported, it works fine in VFO mode,
but does not when operating in memory mode.

Gary McDuffie
AG0N
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net