Peter,
Check out the high amperage 13,8 volt power supplies offered by Samlex America at the following link, and in particular their 100-amp -plus (continuous) supplies where the fans do not activate for low draws. You had mentioned something about price not being so important. These ain't cheap. 73 de Mark .w2or. https://www.samlexamerica.com/products/ProductsList.aspx?cid=S3 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I find Mark's point very important. Obtain and use a supply which is
more than adequate for the service or load. Thus a 25 amp supply feeding a radio drawing 20+ amps will need lots of cooling. This is not the way to do it. Get a 50 amp supply for a radio drawing 20+ amps and the fan(s) will likely never come on. Go the cheap way and get the cheap results. Do it right and be happy. Don't be a cheap ham and then complain about the product you purchased. There is more to choosing a power supply than volts and amps. How about duty cycle? And CCS rated supplies vs. ICAS rated supplies. Humm....... 73 Bob, K4TAX On 6/9/2019 2:12 PM, Mark Murray via Elecraft wrote: > Peter, > > Check out the high amperage 13,8 volt power supplies offered by Samlex > America at the following link, and in particular their 100-amp -plus > (continuous) supplies where the fans do not activate for low draws. You had > mentioned something about price not being so important. These ain't cheap. > 73 de Mark .w2or. > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I use an IOTA DLS-55 SMPS power supply (https://www.iotaengineering.com/
dls55.htm). It provides 55 amps, doesn’t produce RFI, is audibly quiet, and rugged. Mine is mounted under the radio table and is on 24/7/365.. I never hear it. Iota also makes them in other output currents and voltages. Ken WA2LBI On Sun, Jun 9, 2019 at 3:27 PM Bob McGraw K4TAX <[hidden email]> wrote: > I find Mark's point very important. Obtain and use a supply which is > more than adequate for the service or load. Thus a 25 amp supply > feeding a radio drawing 20+ amps will need lots of cooling. This is > not the way to do it. Get a 50 amp supply for a radio drawing 20+ amps > and the fan(s) will likely never come on. Go the cheap way and get > the cheap results. Do it right and be happy. Don't be a cheap ham > and then complain about the product you purchased. > > There is more to choosing a power supply than volts and amps. How about > duty cycle? And CCS rated supplies vs. ICAS rated supplies. Humm....... > > 73 > > Bob, K4TAX > > > On 6/9/2019 2:12 PM, Mark Murray via Elecraft wrote: > > Peter, > > > > Check out the high amperage 13,8 volt power supplies offered by Samlex > > America at the following link, and in particular their 100-amp -plus > > (continuous) supplies where the fans do not activate for low draws. You > had > > mentioned something about price not being so important. These ain't > cheap. > > 73 de Mark .w2or. > > > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Bob McGraw - K4TAX
The issue with oversizing it is (for the energy conscious) a linear
supply demands more, ALL the time (it's inefficient with energy). In some places it matters because of the KwH costs. pennies turn into dollars. (Not here, I was used to the higher prices and after I moved here, I just stopped caring because the costs were 1/3 or less. I've even been known to <gasp> run the air conditioner here!) Rick nhc On 6/9/2019 12:26 PM, Bob McGraw K4TAX wrote: > I find Mark's point very important. Obtain and use a supply which is > more than adequate for the service or load. Thus a 25 amp supply > feeding a radio drawing 20+ amps will need lots of cooling. This is > not the way to do it. Get a 50 amp supply for a radio drawing 20+ > amps and the fan(s) will likely never come on. Go the cheap way > and get the cheap results. Do it right and be happy. Don't be a > cheap ham and then complain about the product you purchased. > > There is more to choosing a power supply than volts and amps. How > about duty cycle? And CCS rated supplies vs. ICAS rated supplies. > Humm....... > > 73 > > Bob, K4TAX > > > On 6/9/2019 2:12 PM, Mark Murray via Elecraft wrote: >> Peter, >> >> Check out the high amperage 13,8 volt power supplies offered by Samlex >> America at the following link, and in particular their 100-amp -plus >> (continuous) supplies where the fans do not activate for low draws. >> You had >> mentioned something about price not being so important. These ain't >> cheap. >> 73 de Mark .w2or. >> > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Ken Winterling
Somewhere around 1980 I was talked into buying a power supply at a hamfest by my good friend who was a great technician. He told me it was a terrific deal. He was right. I don't remember what I paid for it but I know it was lessthan $100. It was a 56 amp rack mounted Llamda metered supply. The model is an LM G12-M. I believe it weighs about 75 pounds. I used to have it in a relay rack at my old QTH shack. In my present shack I have it sitting on a furnituredolly which makes it easy to roll around on the floor. It sits under my desk. It developed an audible arc when turned on so I leave it on 24 - 7. I'm sure the new cost of it would be pretty high but I'm so glad I followed my friend's advice tobuy it. No RFI and no fans.
BillK3WJV On Sunday, June 9, 2019, 4:30:07 PM EDT, Ken Winterling <[hidden email]> wrote: I use an IOTA DLS-55 SMPS power supply (https://www.iotaengineering.com/ dls55.htm). It provides 55 amps, doesn’t produce RFI, is audibly quiet, and rugged. Mine is mounted under the radio table and is on 24/7/365.. I never hear it. Iota also makes them in other output currents and voltages. Ken WA2LBI On Sun, Jun 9, 2019 at 3:27 PM Bob McGraw K4TAX <[hidden email]> wrote: > I find Mark's point very important. Obtain and use a supply which is > more than adequate for the service or load. Thus a 25 amp supply > feeding a radio drawing 20+ amps will need lots of cooling. This is > not the way to do it. Get a 50 amp supply for a radio drawing 20+ amps > and the fan(s) will likely never come on. Go the cheap way and get > the cheap results. Do it right and be happy. Don't be a cheap ham > and then complain about the product you purchased. > > There is more to choosing a power supply than volts and amps. How about > duty cycle? And CCS rated supplies vs. ICAS rated supplies. Humm....... > > 73 > > Bob, K4TAX > > > On 6/9/2019 2:12 PM, Mark Murray via Elecraft wrote: > > Peter, > > > > Check out the high amperage 13,8 volt power supplies offered by Samlex > > America at the following link, and in particular their 100-amp -plus > > (continuous) supplies where the fans do not activate for low draws. You > had > > mentioned something about price not being so important. These ain't > cheap. > > 73 de Mark .w2or. > > > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I have several Power Werx switchers and prefer them for their size over
the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I have an Astron RS35 power Supply purchased in 1991. There was a period where I didn’t use it for ten years. Now it’s in use daily and so far it continues to be totally quiet.
Alan K7FH > On Jun 10, 2019, at 3:56 AM, Bill <[hidden email]> wrote: > > I have several Power Werx switchers and prefer them for their size over the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. > > It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. > > Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? > > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I have twelve RS-35M power supplies and all are completely quiet.
----- Original Message ----- From: "Alan Corbeth" <[hidden email]> To: "Bill" <[hidden email]> Cc: "Elecraft International Group" <[hidden email]> Sent: Tuesday, June 11, 2019 12:04:02 AM Subject: Re: [Elecraft] Silent power supply for a K3s I have an Astron RS35 power Supply purchased in 1991. There was a period where I didn’t use it for ten years. Now it’s in use daily and so far it continues to be totally quiet. Alan K7FH > On Jun 10, 2019, at 3:56 AM, Bill <[hidden email]> wrote: > > I have several Power Werx switchers and prefer them for their size over the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. > > It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. > > Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? > > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Alan Corbeth
The Astrons are quiet and pretty reliable. I have had a RS20 since 1980
and the only problem I had was cured by replacing the regulator chip about 35 years ago. Bob, N7XY On 6/10/19 5:04 PM, Alan Corbeth wrote: > I have an Astron RS35 power Supply purchased in 1991. There was a period where I didn’t use it for ten years. Now it’s in use daily and so far it continues to be totally quiet. > > Alan > K7FH > >> On Jun 10, 2019, at 3:56 AM, Bill <[hidden email]> wrote: >> >> I have several Power Werx switchers and prefer them for their size over the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. >> >> It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. >> >> Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? >> >> >> ______________________________________________________________ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:[hidden email] >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to [hidden email] > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
Another vote for the Astron Power Supplies they work well.
Use the shortest run between the PS and radio you can and of a heavy gauge wire. On Tuesday, June 11, 2019, 6:15:14 PM EDT, Bob Nielsen - N7XY <[hidden email]> wrote: The Astrons are quiet and pretty reliable. I have had a RS20 since 1980 and the only problem I had was cured by replacing the regulator chip about 35 years ago. Bob, N7XY On 6/10/19 5:04 PM, Alan Corbeth wrote: > I have an Astron RS35 power Supply purchased in 1991. There was a period where I didn’t use it for ten years. Now it’s in use daily and so far it continues to be totally quiet. > > Alan > K7FH > >> On Jun 10, 2019, at 3:56 AM, Bill <[hidden email]> wrote: >> >> I have several Power Werx switchers and prefer them for their size over the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. >> >> It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. >> >> Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? >> >> >> ______________________________________________________________ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:[hidden email] >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to [hidden email] > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I've found a good source for power supply wire for the DC connections.
Automotive primary wire, #10 AWG. This wire is made using many small strands which make it very flexible. Various colors are available. I use Red {DC Pos}, Black {DC Neg} and White {equipment bonding wire}. Also I use the proper size for the wire and screw ring terminals {no spade or Y lugs} fitted on each end. I'm and old fashion fellow and and was taught to crimp with the correct crimping tool. I've seen too many hams use the "mash-on" method, thus using what ever tool happens to be in the tool box. A proper crimping tool is designed for the specific connector and sleeve size and does not distort the sleeve. Yea, a good crimping tool may cost you $25 to $35 but it is sure worth it not having to worry about lousy connections. As a test, crimp a lug on a piece of wire. Using pliers, try to pull it off. If you can, it may be the wrong size lug for the wire OR it is not properly crimped. If the wire breaks first, you have a good crimp. 73 Bob, K4TAX On 6/12/2019 8:17 AM, Harry Yingst via Elecraft wrote: > Another vote for the Astron Power Supplies they work well. > > Use the shortest run between the PS and radio you can and of a heavy gauge wire. > > > > On Tuesday, June 11, 2019, 6:15:14 PM EDT, Bob Nielsen - N7XY <[hidden email]> wrote: > > The Astrons are quiet and pretty reliable. I have had a RS20 since 1980 > and the only problem I had was cured by replacing the regulator chip > about 35 years ago. > > Bob, N7XY > > On 6/10/19 5:04 PM, Alan Corbeth wrote: >> I have an Astron RS35 power Supply purchased in 1991. There was a period where I didn’t use it for ten years. Now it’s in use daily and so far it continues to be totally quiet. >> >> Alan >> K7FH >> >>> On Jun 10, 2019, at 3:56 AM, Bill <[hidden email]> wrote: >>> >>> I have several Power Werx switchers and prefer them for their size over the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. >>> >>> It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. >>> >>> Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? >>> >>> >>> ______________________________________________________________ >>> Elecraft mailing list >>> Home: http://mailman.qth.net/mailman/listinfo/elecraft >>> Help: http://mailman.qth.net/mmfaq.htm >>> Post: mailto:[hidden email] >>> >>> This list hosted by: http://www.qsl.net >>> Please help support this email list: http://www.qsl.net/donate.html >>> Message delivered to [hidden email] >> ______________________________________________________________ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:[hidden email] >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to [hidden email] > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Elecraft mailing list
Linear PSs are not noisy as far as I know. You're comparing apples and
oranges!! ;-)) Bert VE3NR On 6/12/2019 9:17 AM, Harry Yingst via Elecraft wrote: > Another vote for the Astron Power Supplies they work well. > > Use the shortest run between the PS and radio you can and of a heavy gauge wire. > > > > On Tuesday, June 11, 2019, 6:15:14 PM EDT, Bob Nielsen - N7XY <[hidden email]> wrote: > > The Astrons are quiet and pretty reliable. I have had a RS20 since 1980 > and the only problem I had was cured by replacing the regulator chip > about 35 years ago. > > Bob, N7XY > > On 6/10/19 5:04 PM, Alan Corbeth wrote: >> I have an Astron RS35 power Supply purchased in 1991. There was a period where I didn’t use it for ten years. Now it’s in use daily and so far it continues to be totally quiet. >> >> Alan >> K7FH >> >>> On Jun 10, 2019, at 3:56 AM, Bill <[hidden email]> wrote: >>> >>> I have several Power Werx switchers and prefer them for their size over the heavy analog supplies. Fans are not a problem (actually, I hear nothing from them at all) - IF you design your radio desk for proper equipment placement. Place the power supply at your right hand - and you WILL hear noise, XFMR, fan, etc. >>> >>> It is amazing what proper station design/construction can do for making silence. Open faced metal shelving and bare desktops don't cut it. >>> >>> Just for grins, I put one of those Nanoxia fans in my IC-7300 and silenced it completely. Worth the few dollars and effort. No temperature changes noted. Hmmm - KPA500????? >>> >>> >>> ______________________________________________________________ >>> Elecraft mailing list >>> Home: http://mailman.qth.net/mailman/listinfo/elecraft >>> Help: http://mailman.qth.net/mmfaq.htm >>> Post: mailto:[hidden email] >>> >>> This list hosted by: http://www.qsl.net >>> Please help support this email list: http://www.qsl.net/donate.html >>> Message delivered to [hidden email] >> ______________________________________________________________ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:[hidden email] >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html >> Message delivered to [hidden email] > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
Regarding "heavy gauge wire", I suggest one measure the voltage drop
using a DVM connected direct between the power supply Pos terminal and the radio Pos terminal. Likewise do the same for the Neg DC line. Put the radio in CW mode and close the key for rated output. If one finds more than 0.25 volts drop in either the Pos or Neg line, I'd say that attention to the power cable and connectors would be in order. Also measure between radio ground and power supply ground. Again a voltage value greater than 0.25 volts indicates attention to the power distribution system and station equipment grounding is needed. 73 Bob, K4TAX On 6/12/2019 9:17 AM, Harry Yingst via Elecraft wrote: >> Another vote for the Astron Power Supplies they work well. >> >> Use the shortest run between the PS and radio you can and of a heavy >> gauge wire. >> >> >> ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
After consulting copper wire tables and typical connection resistances,
I can present the following analysis for a 20 amp load: Often hams power their 100 watt transceivers through DC distribution devices such as a RigRunner which will contribute to the voltage drop. Also in-line fuses will contribute to voltage drop. Connection resistance contributes .05 volt loss under a 20 amp load for each contact point, you have 6 contact points in the path for a fused RigRunner plus two in the APP connector at the transceiver, plus the connection to the power supply for a total of 10 contact points. You have to consider the negative path as well as the positive. So that is a total of 0.5 volts of the total voltage drop. By contrast, a 5 foot length under a 20 amp load of #12 wire has 0.1588 ohms (in both conductors) for a voltage drop of 0.3176 volts, and #10 wire a drop of 0.1998 volts. So conclusion is that while increasing the wire size can reduce the voltage drop, the main contributor is in the power distribution system. A path direct from the power supply terminals can be expected to have a 0.5 volt drop with 5 feet of #12 wire to the inside of the K3. and #10 wire can have a 0.4 volt drop - the difference is only slightly significant. Conclusion - in a 5 foot power cable run, the difference between #10 and #12 wire is only 0.1 volts (0.05 volts in each of the positive and negative leads) - the major contributor is the number of contact points. So for those who choose to measure the voltage drop from the power supply terminals to the APP connector on the outside of the K3, you should measure about 0.2 volts in each conductor with #12 wire and 0.15 volts with #10 wire. If it is much more than that, check your power supply connection tightness and your crimp connections. Run the transceiver direct from a power supply using ring terminals instead of routing through a power distribution accessory. 73, Don W3FPR On 6/12/2019 6:29 PM, Bob McGraw K4TAX wrote: > Regarding "heavy gauge wire", I suggest one measure the voltage drop > using a DVM connected direct between the power supply Pos terminal and > the radio Pos terminal. Likewise do the same for the Neg DC line. Put > the radio in CW mode and close the key for rated output. If one finds > more than 0.25 volts drop in either the Pos or Neg line, I'd say that > attention to the power cable and connectors would be in order. Also > measure between radio ground and power supply ground. Again a voltage > value greater than 0.25 volts indicates attention to the power > distribution system and station equipment grounding is needed. > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
On 2019-06-12 7:55 PM, Don Wilhelm wrote: > Connection resistance contributes .05 volt loss under a 20 amp load > for each contact point, you have 6 contact points in the path for a > fused RigRunner plus two in the APP connector at the transceiver, > plus the connection to the power supply for a total of 10 contact > points. You have to consider the negative path as well as the > positive. So that is a total of 0.5 volts of the total voltage drop. This assumes the APP connections into and out of the RigRunner are assembled correctly (contacts properly aligned). If they are not, the contact resistance will be significantly higher. Further, the 20A current (and the voltage drop I^2*R) may be significantly higher in the cable between the power supply and RigRunner. Again, this will result in *MORE THAN* 0.5 volts of total voltage drop when using a RigRunner type power distribution system. Further, while one may measure 20A in transmit (using the K3 internal "meter") there is a significant time constant, particularly in SSB operation. The actual *peak* current may be closer to 30 - 35A than to 17 - 20A. Since voltage drop in power supply cables and power distribution system are related to the *current squared* the actual *maximum* voltage drop (and loss of voltage regulation, increase in transmit IMD, etc.) will be worse that the static analysis would indicate. 73, ... Joe, W4TV On 2019-06-12 7:55 PM, Don Wilhelm wrote: > After consulting copper wire tables and typical connection resistances, > I can present the following analysis for a 20 amp load: > > Often hams power their 100 watt transceivers through DC distribution > devices such as a RigRunner which will contribute to the voltage drop. > Also in-line fuses will contribute to voltage drop. > > Connection resistance contributes .05 volt loss under a 20 amp load for > each contact point, you have 6 contact points in the path for a fused > RigRunner plus two in the APP connector at the transceiver, plus the > connection to the power supply for a total of 10 contact points. You > have to consider the negative path as well as the positive. So that is > a total of 0.5 volts of the total voltage drop. > > By contrast, a 5 foot length under a 20 amp load of #12 wire has 0.1588 > ohms (in both conductors) for a voltage drop of 0.3176 volts, and #10 > wire a drop of 0.1998 volts. > > So conclusion is that while increasing the wire size can reduce the > voltage drop, the main contributor is in the power distribution system. > > A path direct from the power supply terminals can be expected to have a > 0.5 volt drop with 5 feet of #12 wire to the inside of the K3. and #10 > wire can have a 0.4 volt drop - the difference is only slightly > significant. > > Conclusion - in a 5 foot power cable run, the difference between #10 and > #12 wire is only 0.1 volts (0.05 volts in each of the positive and > negative leads) - the major contributor is the number of contact points. > > So for those who choose to measure the voltage drop from the power > supply terminals to the APP connector on the outside of the K3, you > should measure about 0.2 volts in each conductor with #12 wire and 0.15 > volts with #10 wire. If it is much more than that, check your power > supply connection tightness and your crimp connections. > > Run the transceiver direct from a power supply using ring terminals > instead of routing through a power distribution accessory. > > 73, > Don W3FPR > > On 6/12/2019 6:29 PM, Bob McGraw K4TAX wrote: >> Regarding "heavy gauge wire", I suggest one measure the voltage drop >> using a DVM connected direct between the power supply Pos terminal and >> the radio Pos terminal. Likewise do the same for the Neg DC line. >> Put the radio in CW mode and close the key for rated output. If one >> finds more than 0.25 volts drop in either the Pos or Neg line, I'd say >> that attention to the power cable and connectors would be in order. >> Also measure between radio ground and power supply ground. Again a >> voltage value greater than 0.25 volts indicates attention to the power >> distribution system and station equipment grounding is needed. >> ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Elecraft mailing list
Easy way out of this mess, if a little expensive...
A big PSU dedicated to the rig(s), implementing "Remote Sensing" so at a distribution point close to the radio(s) the DC voltage is held constant, irrespective of the cable length from the PSU. This power supply should have a proper overload (and over voltage) protection scheme too, not only to protect itself, but the radio(s) also. And safety resistors between + and +s, also between - and -s terminals. (Prevents expensive embarrassment, if a sense line fails!) Then use a smaller PSU for the low power accessories, with suitable fusing. Any QRO power amp, needing really high current, should have it's own independent dedicated PSU, again with remote sensing to keep the voltage at the PA as near constant as it can be, and the resulting high DC currents, purely between the PA and it's PSU. Just my way of doing things, to keep the high DC currents out of the RF cabling. Google "power supply remote sensing" for more info. 73. Dave G0WBX. -- Created on and sent from a Unix like PC running and using free and open source software: ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Don Wilhelm
Interesting data, Don. I wonder if there is any information about
resistance variations between soldered and crimped terminals. One might think that, with stranded wire, even a good crimp connection might not solidly involve all of the strands, and might additionally deteriorate with time since oxygen could get between the strands. A good solder job should wet the wire through and (additionally) exclude oxygen. This wouldn't be easy to measure, for sure, but these engineers are cleaver people! 73 - George, W3HBM On 6/12/2019 7:55 PM, Don Wilhelm wrote: > [This message came from an external source. If suspicious, report to > [hidden email]<mailto:[hidden email]>] > > After consulting copper wire tables and typical connection resistances, > I can present the following analysis for a 20 amp load: > > Often hams power their 100 watt transceivers through DC distribution > devices such as a RigRunner which will contribute to the voltage drop. > Also in-line fuses will contribute to voltage drop. > > Connection resistance contributes .05 volt loss under a 20 amp load for > each contact point, you have 6 contact points in the path for a fused > RigRunner plus two in the APP connector at the transceiver, plus the > connection to the power supply for a total of 10 contact points. You > have to consider the negative path as well as the positive. So that is > a total of 0.5 volts of the total voltage drop. > > By contrast, a 5 foot length under a 20 amp load of #12 wire has 0.1588 > ohms (in both conductors) for a voltage drop of 0.3176 volts, and #10 > wire a drop of 0.1998 volts. > > So conclusion is that while increasing the wire size can reduce the > voltage drop, the main contributor is in the power distribution system. > > A path direct from the power supply terminals can be expected to have a > 0.5 volt drop with 5 feet of #12 wire to the inside of the K3. and #10 > wire can have a 0.4 volt drop - the difference is only slightly > significant. > > Conclusion - in a 5 foot power cable run, the difference between #10 and > #12 wire is only 0.1 volts (0.05 volts in each of the positive and > negative leads) - the major contributor is the number of contact points. > > So for those who choose to measure the voltage drop from the power > supply terminals to the APP connector on the outside of the K3, you > should measure about 0.2 volts in each conductor with #12 wire and 0.15 > volts with #10 wire. If it is much more than that, check your power > supply connection tightness and your crimp connections. > > Run the transceiver direct from a power supply using ring terminals > instead of routing through a power distribution accessory. > > 73, > Don W3FPR > > On 6/12/2019 6:29 PM, Bob McGraw K4TAX wrote: >> Regarding "heavy gauge wire", I suggest one measure the voltage drop >> using a DVM connected direct between the power supply Pos terminal and >> the radio Pos terminal. Likewise do the same for the Neg DC line. Put >> the radio in CW mode and close the key for rated output. If one finds >> more than 0.25 volts drop in either the Pos or Neg line, I'd say that >> attention to the power cable and connectors would be in order. Also >> measure between radio ground and power supply ground. Again a voltage >> value greater than 0.25 volts indicates attention to the power >> distribution system and station equipment grounding is needed. >> > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
* On 2019 16 Jun 18:50 -0500, Kidder, George wrote:
> Interesting data, Don. I wonder if there is any information about > resistance variations between soldered and crimped terminals. One might > think that, with stranded wire, even a good crimp connection might not > solidly involve all of the strands, and might additionally deteriorate > with time since oxygen could get between the strands. A good solder job > should wet the wire through and (additionally) exclude oxygen. This > wouldn't be easy to measure, for sure, but these engineers are cleaver > people! For what it is worth, the company I worked for prohibited the use of soldered connectors for terminating bonding or power wiring. Especially with regard to bonding, dissipating any lightning strike energy through a soldered connector could cause it to enough to melt the solder. In doing some microwave site upgrades I did pull out a previous generation of bonding wiring that was soldered and some connectors had signs of being heated since installation. In my shack I use crimp connectors and a quality crimping tool with no problems. 73, Nate, N0NB -- "The optimist proclaims that we live in the best of all possible worlds. The pessimist fears this is true." Web: https://www.n0nb.us GPG key: D55A8819 GitHub: N0NB ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Kidder, George
George,
Solid wire will eventually break if it is flexed - and it will break right where the terminals are attached. Stranded wire that is soldered will also break - right where the end of the solder that wicked up the wire stops. The best is stranded wire with crimped connections made with a proper crimping tool. Done properly, that should result in an air-tight connection that should not oxidize. In order to do that, you must use a crimping tool that is sized for the wire and terminal that you are using. Crimping with just any tool will "not get it". If you do not have the proper crimping tool, soldering is OK, but support the wire for about 2 inches away from the soldered terminal so there is no chance that it can flex. 73, Don W3FPR On 6/16/2019 7:22 PM, Kidder, George wrote: > Interesting data, Don. I wonder if there is any information about > resistance variations between soldered and crimped terminals. One might > think that, with stranded wire, even a good crimp connection might not > solidly involve all of the strands, and might additionally deteriorate > with time since oxygen could get between the strands. A good solder job > should wet the wire through and (additionally) exclude oxygen. This > wouldn't be easy to measure, for sure, but these engineers are cleaver > people! ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Kidder, George
"but these engineers are cleaver people!"
Engineers with slide rules are arguably less of a threat than those with cleavers. Resistance is futile... 73, Andy, k3wyc ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |