I KNOW this is cockpit error (it always is) so I’m hoping someone can tell
be what I am doing wrong. I just installed the two KSYN3A synthesizer boards in my K3 main and sub and successfully upgraded firmware to 5.14, and performed the installation check: SYN1 OK and SYN2 OK. When I tried to do the xmit gain calibration at 50 watts, this is the message I received: “Xmit gain calibration failed because transmit power did not reach the expected value. 50 watt calibration failed.” I even tried it at 5 watts and still didn’t work. Yes, I cycled K3 off and then on after firmware upgrade. Mike, W4UM ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
|
Did you attach a dummy load to an antenna port? (Later to another port
for the flea power calibration.) Did you tell the calibration program to use the port with the dummy load attached? (DOH!!!) Hey, we've all been there. It's best to ask the dummy questions first, they're the simplest to miss. Rick nhc On 4/27/2015 1:16 PM, Michael Raskin wrote: > I KNOW this is cockpit error (it always is) so I’m hoping someone can > tell be what I am doing wrong. I just installed the two KSYN3A > synthesizer boards in my K3 main and sub and successfully upgraded > firmware to 5.14, and performed the installation check: SYN1 OK and > SYN2 OK. When I tried to do the xmit gain calibration at 50 watts, > this is the message I received: “Xmit gain calibration failed because > transmit power did not reach the expected value. 50 watt calibration > failed.” I even tried it at 5 watts and still didn’t work. Yes, I > cycled K3 off and then on after firmware upgrade. > > Mike, W4UM ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
|
In reply to this post by Michael Raskin
Mike,
Are you using the latest K3Utility? You can do the TX Gain Calibration manually through the menu. Give that a try on a few bands - if it is successful, try the K3 Utility process again, or just do all bands manually. The manual procedure does the same thing as K3 Utility, except the Utility makes it 'pain-free'. 73, Don W3FPR On 4/27/2015 4:16 PM, Michael Raskin wrote: > I KNOW this is cockpit error (it always is) so I’m hoping someone can > tell be what I am doing wrong. I just installed the two KSYN3A > synthesizer boards in my K3 main and sub and successfully upgraded > firmware to 5.14, and performed the installation check: SYN1 OK and > SYN2 OK. When I tried to do the xmit gain calibration at 50 watts, > this is the message I received: “Xmit gain calibration failed because > transmit power did not reach the expected value. 50 watt calibration > failed.” I even tried it at 5 watts and still didn’t work. Yes, I > cycled K3 off and then on after firmware upgrade. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
| Free forum by Nabble | Edit this page |