Hi
This is normal most of the time the pot will be at max. Don't worry be happy
Don Brown
I have built 5 of them number 6 on its way
----- Original Message -----
From: Paul<mailto:
[hidden email]>
To:
[hidden email]<mailto:
[hidden email]>
Sent: Thursday, July 01, 2004 7:06 PM
Subject: [Elecraft] Transverter Alignment Procedure Part 1
Reflector Members,
Instructions say :
Measure the TP2 near L1 in the upper left corner of the RF board. This is the low-noise amplifier (LNA) bias level. Adjust R13 for between 200 and 275 mV (250 mV nominal).
All I can get from R13 fully clockwise is 245 mV. Will this present a problem being at the "fully clockwise" position and being under the rating that is considered the "nominal" setting? This is an identical reading for two separate transverters.
Paul
K8QT