Roy,
Be certain you have T-R set to HOLD. See page 89 of the manual. The
T-R setting determines the delay, and the 8R hold or normal settings
will influence the behavior of the 8R signal (that signal controls the
K2 "keyout" timing.
At what code speeds - yes at slow speeds, the relays will "chatter" no
matter what the settings, but at 20+ wpm, the relays should hold in
between characters.
The K2 uses silent electronic T/R switching, but the XVxxx transverters
use relays for T/R functions.
73,
Don w3FPR
On 4/2/2011 1:11 AM, Leroy Marion wrote:
> I just finished a XV50 transverter. Using it with a K2
>
> with the KI02 control.
>
> It seems to work OK when keyed for SSB. When I use
>
> CW, its relays click and chatter like mad. Do I have
>
> some thing set wrong?
>
>
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.html